![FRTek PrimAer 28 Operating Manual Download Page 60](http://html.mh-extra.com/html/frtek/primaer-28/primaer-28_operating-manual_2340219060.webp)
PRIVATE AND CONFIDENTIAL © 2020 FRTEK CO., LTD.
60
PrimAer 28GHz
Operating Manual
③
Function List
This item is to use implemented additional functions. The 'History' function, temperature/power 'Table'
manage function, the firm ware download function, and the 'Debug' function can be used.
- History : Item to use
‘
Alarm History
’
function. Item to check connected unit's alarm history.
- Table : Item to create/manage output table and temperature table per each unit.
- Download : Item to download firmware per each unit.
- Debug : Item to check real-time debug messages from the CPU configured for each unit.
④
SU System
This item is to check SU system information and alarm, the information list is as below.
- F/W Ver : MCU Firmware Version
- FPGA Ver : FPGA Firmware Version
- Cur Time : Current Time
- Rpt Type : Repeater Type
- Rpt Maker : Repeater Maker
- Cur Temper : Current Temperature
- Temperature H : Temperature Upper Setting
- Temperature L : Temperature Lower Setting
- SU ID : Item to set the ID to connect SU cascade to upper DU or SU
- DL/UL Test : DL/UL fixed mode setting for testing on TDD operation mode
- INT Status : Initialize Status, MCU booting and connection status when DU is ON
- DC Alarm : Alarm to monitor DC input power -53.5V status of the DU
- Temp Alarm : DU internal temperature
- TSYNC Link Alarm : TDD sync signal of outside base station signal
- AC Alarm : Alarm to monitor Rectifier AC input power 100 ~ 240V status
- BAT Alarm : Alarm to monitor battery operation status
⑤
MVBX Status
This item is to monitor base station information SSP, SNR, RSRP real-time.