28
3. Web Access Password
To set a password to deter configuration changes by network hacks:
•
Choose
User ID/Password
•
Type in the old password (the default is ‘calypso’)
•
Enter/re-enter the new password
•
Click
Save Settings
in the top section
•
Select
Admin
from the
Security Level
drop-down
•
Click
Save Settings
in the bottom section
4. Advanced Ethernet Settings
•
Choose
Ethernet
. As needed, make the following communication settings adjustments:
•
Automatic IP Configuration (DHCP): Use only if you are thoroughly familiar with DHCP configuration
•
IP Address
•
IP Subnet Mask (for your computer network grouping; default is 255.255.255.0)
•
Router IP Address of your subnet
•
Primary NameServer IP Address (default is 192.168.1.1)
•
Secondary NameServer IP Address
•
Click
Save Settings
in the top section
The device port configuration and System MAC Address sections consist of defaults generally not required for mod-
ification. The Web Server Port (set at 80) is also static and is visible here for informational purposes only. Next, the
Remote Management Port is a Controller Network Action Protocol (CNAP) registered port set at 7262 for command-
line (CNAP) functions only. It is used by external software to send commands to the controller. The Remote Port
Idle Timeout field’s default setting is Disabled. When active, it sets the duration (in minutes) before the controller
releases the remote communication port after a period of inactive controller communication. If a special case arises
where your system does require configuration, contact FrontRow Technical Services at customercare@gofrontrow.
com for assistance.