7
Insert the DC terminals into the respective
slot until they engage.
8
Fasten the screws of the cable guide to
the housing using a screwdriver (TX20)
and a torque of 1.3-1.5 Nm.
NOTE!
Do not use a drill driver as this could
cause overturning.
A possible consequence of overturning is,
for example, damaging the strain-relief
device.
IMPORTANT!
Information for connection on the battery side can be found in the Installation Instructions
from the relevant manufacturer.