![Fronius Symo 12.0-3 208-240 Operating Instructions Manual Download Page 62](http://html1.mh-extra.com/html/fronius/symo-12-0-3-208-240/symo-12-0-3-208-240_operating-instructions-manual_2339223062.webp)
62
Fronius Symo Advanced
15.0-3 480
Input Data
MPP voltage range
350 - 800 V DC
Input voltage range (at 1,000 W/m²/14 °F in an open circuit)
200 - 1,000 V DC
Max. input current (MPP1/MPP2)
(MPP1 + MPP2)
33.0/25.0 A
51 A
Max. short circuit current of solar modules (I
SC PV
) (MPP1/MPP2)
49.5/37.5 A
Max. backfeed current from AC grid
1)
0.0 A
2)
Output Data
Nominal output power (P
nom
)
14,995 W
Max. output power (+104°F)
14,995 W
Max. output power (+140°F)
at 440 V
12,200 W
at 480 V
14,400 W
Phases
3 ~ NPE
Nominal grid voltage
at 440 V
254 V/440 V
at 480 V
277 V/480 V
Operating range AC voltage
-12 ... +10%
Adjustment range for grid voltage
127 - 322 V/220 - 558 V
Max. continuous output current at V
nom
at 440 V
19.7 A
at 480 V
18.0 A
AC recommended min. overcurrent protection
at 440 V
25.0 A
at 480 V
25.0 A
Max. output residual current per duration
30.9 A/150.4 ms
Nominal frequency
50/60 Hz
Total harmonic distortion
< 1.5%
Power factor (cos phi)
0 - 1 ind./cap.
3)
General Data
Maximum efficiency
98.00%
CEC efficiency
at 440 V
at 480 V
97.00%
Cooling
Controlled forced-air ventilation
Protection class
NEMA 4X
Dimensions h x w x d
28.5 x 20.1 x 8.9 in.
725 x 510 x 225 mm
Weight (full/lite version)
95.7/95.0 lbs. (43.4/43.1 kg)
Permissible ambient temperature
-40°F to +140°F (-40°C to +60°C)
Permissible storage temperature
-40°F to +158 °F (-40°C to +70 °C)
Permissible humidity
0 - 100%
Noise emission
65 dB(A) (ref. 1pW)
Protection Devices
Reverse polarity protection
Integrated
Stand-alone operation protection
Integrated
Arc detection/interruption
Integrated