34
Menu Items in the Setup Menu
Standby
Manual activation/deactivation of the standby mode
-
No energy is fed into the grid.
-
The Startup LED lights up orange.
-
The display switches between STANDBY/ENTER
-
In standby mode, no other menu item can be accessed or set in the menu level.
-
The automatic switching to the ‘NOW’ menu item after 2 minutes if no key is pressed
is not activated.
-
The standby mode can only be deactivated manually by pressing the ‘Enter’ key.
-
The grid power feed operation can be resumed at any time by pressing the ‘Enter’ key,
if no error (state code) is displayed
Setting the standby mode (manual shutoff for feeding energy into the grid):
Select the ‘Standby’ entry
Press the ‘Enter’ function key
The display alternates between ‘STANDBY’ and ‘ENTER.’
The Standby mode is now activated.
The Startup LED lights up orange.
Restoring the grid power feed operation:
In Standby mode, the display alternates between ‘STANDBY’ and ‘ENTER’.
Press the ‘Enter’ function key
to restore the grid power feed operation
The ‘Standby’ entry is displayed.
The inverter also switches to the Startup phase.
After the grid power feed operation is restored, the Operation Status LED lights up green.
WLAN Access
Point
To activate/deactivate the WLAN Access Point. For example, this is required to set up or
adjust the system monitoring using the Datamanager web interface. If no Datamanager is
detected by the inverter, [not available] is displayed
1
2
1
Setting range
WLAN Access Point
[stopped]
Activate WLAN AP?
To activate the WLAN Access Point Press the Enter key
WLAN Access Point
[active]
The SS-ID (SS) and the password (PW) are displayed.