35
EN-US
DATCOM
Check the data communication, entry of the inverter number, protocol settings
USB
Performing firmware updates or saving inverter detail values on a USB thumb drive
Safely remove hardware
To remove a USB thumb drive from the USB A socket on the data communication rack
without losing data.
The USB thumb drive can be removed:
-
When OK is displayed
-
When the "Data Transfer" LED is no longer flashing or lit
Software Update
For updating inverter firmware using a USB thumb drive.
Procedure:
Deactiv. WLAN AP?
To deactivate the WLAN Access Point Press the Enter
key
WLAN Access Point
[not available]
Is displayed if no system monitoring is available on the inverter.
Setting range
Status/inverter number/protocol type
Status
Displays data communication available via Fronius Solar Net or an error that occurred in
data communication
Inverter Number
Number setting (address) of the inverter in a setup with multiple inverters
Setting range
00 - 99 (00 = inverter address 100)
Factory setting
01
IMPORTANT!
Each inverter must be assigned its own address when using multiple in-
verters in a data communications system.
Protocol Type
Defines the communication protocol used to transmit data:
Setting range
Fronius Solar Net / Interface *
Factory setting
Fronius Solar Net
* The interface protocol type only functions without a Fronius Datamanager card. Existing
Fronius Datamanager cards must be removed from the inverter.
Setting range
Safely remove hardware / software update / logging interval