Aquamatic con-
trol
The Aquamatic control contains the controller for a solenoid valve that automatically tops
up the water in the battery to be charged.
Standard setting
-
At the start of the recharging phase, the solenoid valve opens for 12 seconds and
then closes for 4 seconds.
-
This cycle is repeated 26 times.
USER setting
-
Configurable "ON" time (solenoid valve opens) after the end of the main charge
phase.
Charging
The "Charging" option is suitable for actuating a signal lamp for instance. While charging
is in progress, the corresponding relay picks up automatically.
Charge 50%
Like the "Main charge finished" function, the relevant relay switches as soon as the bat-
tery is 50% charged.
Charge 80%
Like the "Main charge finished" function, the relevant relay switches as soon as the bat-
tery is 80% charged.
Charging not
complete
The "Charging not complete" option lends itself to the actuation of an audible alarm
device, for example. If the battery is disconnected from the charger before the charging
process is complete, the relay switches for an adjustable time of 1 to 10 seconds.
Charge finish
The "Charge finish" option is suitable for actuating a signal lamp for instance. Once the
configured charging characteristic is fully completed, the corresponding relay picks up
automatically.
Main charge fin-
ished
The "Main charge finished" option is suitable for actuating a signal lamp for instance.
When the main charge phase finishes, the corresponding relay picks up automatically.
Common error
message
The "Common error message" option is suitable for actuating a signal lamp for instance.
Each time an error is detected, the relevant relay picks up automatically.
Common error +
warning
In the same way as for the "Common error" function, the corresponding relay trips as
soon as an error or warning is detected.
Signal lamp
As an alternative to the charging lights, one or more suitable lamps can be connected to
the relay board to indicate the state of charge or operating status of the charger. These
56