5
Use the "Up/Down" keys to set the desired value (e.g. "24" for the number of battery
cells).
6
Use the "Pause/Start" key to confirm what you have entered.
If one or more relevant settings are changed for the charging process in configuration
mode, you will once again be prompted to confirm acceptance of the changed settings
when exiting configuration mode.
The following settings need to be confirmed when exiting configuration mode:
-
Characteristic
-
Battery capacity in Ah (excluding the RI characteristic)
-
Number of cells
-
Equalising charge ON/OFF
-
CAN protocol
Example:
Changing the characteristic from 3 - UI
(Pb-WET) to 6 - RI (Pb-WET).
If the setting is not confirmed, the charger
returns to configuration mode and the set-
ting can be changed to the desired value.
Settings
Below is a detailed description of the "Settings" menu item for the "Charging settings"
menu item discussed above. Navigation is performed as described in the "Configuration
mode" section.
A list appears with the following selection options:
The individual selection options are explained in greater detail below.
33