
"External start/stop"
The following settings are available for external start/stop:
"Button"
-
The function of the "Pause/Start" button can be simulated by means of an external
button.
Normal
-
Start ON:
Charging starts when an external switch is closed and a battery is detected
or when the charging plug is connected by closing the auxiliary contacts and a bat-
tery is detected.
-
Start OFF:
Charging starts when a battery is connected.
-
Stop ON:
Charging is interrupted when an external switch is opened
or when the charging plug is disconnected by opening the auxiliary contacts.
-
Stop OFF:
The opening of an external switch or the auxiliary contacts is ignored.
“Contact detection”
-
ON:
If a battery is connected when "Start ON" is set and the external start/stop contact is
not closed, the status message (16) "External start/stop is not closed" appears.
If charging has been started when "Stop ON" is set, the external start/stop contact is
opened and the battery is not fully charged, and the status message (16) "External
start/stop is not closed" appears.
-
OFF:
Contact detection is not executed.
“Refill indicator”
The refill indicator is activated as soon as it is necessary to add distilled water to the bat-
tery. The time of the refill request can be defined as follows:
Every x-th week and weekday
-
e.g. refill water every 2nd week on Friday
When "OFF" of set, the refill request does not have to be confirmed.
41
EN