Delay
-
If the battery remains connected to the charger for the duration of the equalising
charge delay ("equalize charge delay"), a special type of charging takes place. This
prevents acid stratification.
-
The parameters for the current (ampere/100 ampere hours), voltage (volt/cell) and
duration of the equalising charge may all be changed.
Weekday
-
Specify the weekday on which the equalising charge is to take place.
-
The parameters for the current (ampere/100 ampere hours), voltage (volt/cell) and
duration of the equalising charge may all be changed.
Manual equalising charge (“Manual”)
-
An equalising charge can be started manually by pressing the relevant key on the
display.
-
The equalising charge starts after a set delay time has been observed. The charge
parameters that have been set are followed.
-
The parameters for the current (ampere/100 ampere hours), voltage (volt/cell) and
duration of the equalising charge may all be changed.
-
This function is only available for Pb-Wet characteristics.
If a setting for the equalising charge is enabled, a symbol on the home screen next to the
set ampere hours or charging time shows whether an equalising charge is being carried
out or can be started.
Delay
"Delay"
"Charge start delay"
-
Delay time (minutes) between the activation time of the charge start and the actual
charge start.
“Charge end delay”
-
Delay time (minutes) between the signaled end of charge (e.g. green indicator) and
the actual end of charge.
"At mains failure restart charging"
-
If this option is activated, the charging process is automatically restarted after a fault
in the electrical network as soon as the electrical network is available again.
"At mains failure"
-
Restart charging
-
Automatic/continue charging
If the "Restart charging" option is activated, the charging process is automatically restar-
ted after a fault in the electrical network as soon as the electrical network is available
again.
If the "Automatic/continue charging" option is activated, the charging process is automat-
ically continued after a fault in the electrical network as soon as the electrical network is
available again.