237
EN
slaghammer On_1/Off_0
Function for removing slag at the end of the wire electrode for CMT characteristics
Unit
-
Range
-
Slope 1 Sl1
for setting the time during which the starting current is decreased to
the welding current
(SL)
Unit
[s]
Range
0.1 - 9.9
Slope 2 Sl2
for setting the time during which the welding current is decreased to
the final current
(SL)
Unit
[s]
Range
0.1 - 9.9
Special 2-step mode
for presetting the special 2-step mode (= selecting jobs and groups
via the welding torch trigger)
(S2t)
Unit
-
Range
normal/1
Special 4-step mode
for presetting the special 4-step mode (= switching from one job to the
next using the "JobMaster" welding torch)
(S4t)
Unit
-
Range
normal/1
Special dynamic
With the special dynamic, a specific current value can be added to the present welding
current for the duration of the short circuit
Unit
-
Range
0 - 65535
Spot welding time
duration of the spot-welding process
(SPt)
Unit
[s]
Range
0.1 - 5
Standard
for presetting the units standard used by the remote control
(SEt)
Unit
-
Range
metric/inch/lb/gallon
Starting current ls
for setting the starting current for MIG/MAG welding (e.g. aluminium
welding start-up)
(I-S)
Unit
[%]
Range
0 - 200
Starting-current dur. ts
for setting the length of time the starting current is active
(t-S)
Unit
[s]
Range
Off/0.1 - 9.9
Summary of Contents for RCU 5000i
Page 2: ...2 ...
Page 4: ...4 ...
Page 200: ...200 Backup screen All data from the remote control unit are sa ved onto the memory card ...
Page 202: ...202 Restore screen The last Data screen called up appears ...
Page 207: ...207 EN Machine pre sets MIG MAG screen MIG MAG screen appears ...
Page 210: ...210 Machine pre sets e g MIG MAG screen The last Data screen called up appears ...
Page 242: ...242 ...
Page 243: ...Appendix ...
Page 244: ...244 Spare parts list RCU 5000i ...
Page 245: ...245 ...
Page 246: ...246 ...
Page 247: ...247 ...