228
Dynamic
for dynamic correction in the case of standard arc (MIG/MAG manual
welding) or MMA welding
(dYn)
Unit
-
Range
0 - 10
Dynamic correction
for correcting the dynamic range in the case of a standard arc
(dYn)
Unit
-
Range
-0.5 - +5
EN_d_boostdown
for setting the linear current decrease rate following the boost phase for CMT Advanced
characteristics
Unit
[A/ms]
Range
0 - 1000
EN_d_boostup
For setting the linear current rise rate at the start of the boost phase for CMT Advanced
characteristics
Unit
[A/ms]
Range
0 - 1000
EN_I_boost
negative current set value during the boost phase for CMT Advanced characteristics
Unit
[A]
Range
5.0 - 600.0
EN_I_drop_melt
current set value for globule formation at the end of welding for CMT
characteristics
Unit
[A]
Range
3.0 - 500.0
EN_I_sc_wait
negative current set value following the boost phase until the dipping of the wire electrode
into the weld pool for CMT Advanced characteristics
Unit
[A]
Range
5.0 - 600.0
EN_I_sc2
negative current set value with short circuit (CMT Advanced characteristics and CMT Ad-
vanced Pulse characteristics)
Unit
[A]
Range
5.0 - 300.0
EN_t_I_boost
for setting the duration of the boost phase (how long the current set value is active in the
boost phase)
Unit
[ms]
Range
0.00 - 99.98
EN_tau_boostdown
for setting the non-linear current decrease rate following the boost phase for CMT char-
acteristics
Unit
[ms]
Range
Summary of Contents for RCU 5000i
Page 2: ...2 ...
Page 4: ...4 ...
Page 200: ...200 Backup screen All data from the remote control unit are sa ved onto the memory card ...
Page 202: ...202 Restore screen The last Data screen called up appears ...
Page 207: ...207 EN Machine pre sets MIG MAG screen MIG MAG screen appears ...
Page 210: ...210 Machine pre sets e g MIG MAG screen The last Data screen called up appears ...
Page 242: ...242 ...
Page 243: ...Appendix ...
Page 244: ...244 Spare parts list RCU 5000i ...
Page 245: ...245 ...
Page 246: ...246 ...
Page 247: ...247 ...