194
TransTig
4000 Comfort,
TransTig
4000 Comfort MV
Explanation of
footnotes
1)
connected to public mains supply with 230 / 400 V and 50 Hz
2)
d.c. = duty cycle
3)
PCC = interface to the public grid
Dimensions L x W x H (with handle)
560 / 250 / 435 mm
22.0 / 9.8 / 17.1 in.
560 / 250 / 435 mm
22.0 / 9.8 / 17.1 in.
Weight
25,9 kg
57.10 lb.
25,9 kg
57.10 lb.
Mark of conformity
S, CE
S, CE
TT 2500 Comfort MV TT 3000 Comfort MV
TT 4000 Comfort
TT 4000 Comfort MV
Mains voltage
3 x 400 V
3 x 200 - 240 V
3 x 380 - 460 V
Mains voltage tolerance
± 15 %
± 10 %
Mains frequency
50/60 Hz
50/60 Hz
Mains fuse protection (slow-blow)
35 A
63/35 A
Mains connection
1)
Restrictions possible Restrictions possible
Primary continuous power (100% d.c.
2)
) 11.8 kVA
11.5 kVA
Cos phi
0,99
0,99
Welding current range
TIG
3 - 400 A
3 - 400 A
Electrode
10 - 400 A
10 - 400 A
Welding current at
10 min/40 °C (104 °F) 40% d.c.
2)
-
-
10 min/40 °C (104 °F) 45% d.c.
2)
400 A
400 A
10 min/40 °C (104 °F) 60% d.c.
2)
365 A
360 A
10 min/40 °C (104 °F) 100% d.c.
2)
310 A
300 A
Open circuit voltage
86 V
86 V
Working voltage
TIG
10.1 - 26.0 V
10.1 - 26.0 V
Electrode
20.4 - 36.0 V
20.4 - 36.0 V
Striking voltage (U
p
)
9.5 kV
9.5 kV
The arc striking voltage is suitable for manual operation.
Degree of protection
IP 23
IP 23
Type of cooling
AF
AF
Insulation class
F
F
EMC emission class
(in accordance with EN/IEC 60974-10)
A
A
Dimensions L x W x H (with handle)
625 / 290 / 475 mm
24.6 / 11.4 / 18.7 in.
625 / 290 / 475 mm
24.6 / 11.4 / 18.7 in.
Weight
39.8 kg
87.7 lb.
42.0 kg
92.6 lb.
Mark of conformity
S, CE
S, CE, CSA
Summary of Contents for MagicWave 2200 Comfort
Page 2: ...2...
Page 4: ...4...
Page 10: ...10...
Page 23: ...General information...
Page 24: ......
Page 27: ...Control elements and connections...
Page 28: ......
Page 39: ...Installation and commissioning...
Page 40: ......
Page 45: ...Welding...
Page 46: ......
Page 89: ...Setup settings...
Page 90: ......
Page 170: ...170...
Page 171: ...Troubleshooting and maintenance...
Page 172: ......
Page 183: ...183 EN Disposal Dispose of in accordance with the applicable national and local regulations...
Page 184: ...184...
Page 185: ...Appendix...
Page 186: ......
Page 195: ...Spare parts and circuit diagrams...
Page 196: ...196 Spare parts list TransTig MagicWave 2200 Comfort...
Page 197: ...197...
Page 198: ...198 Spare parts list TransTig MagicWave 2500 3000...
Page 200: ...200 Spare parts list TransTig 4000...
Page 201: ...201...
Page 202: ...202 Spare parts list MagicWave 4000...
Page 203: ...203...
Page 204: ...204...
Page 205: ...205 Circuit diagrams MagicWave 2200 Comfort V 12 06 2014...
Page 206: ...206 Circuit diagrams MagicWave 2500 Comfort...
Page 207: ...207 Circuit diagrams MagicWave 3000 Comfort...
Page 208: ...208 Circuit diagrams MagicWave 4000 Comfort V 17 12 2012 1 2...
Page 209: ...209 V 17 12 2012 2 2...
Page 210: ...210 Circuit diagrams TransTig 2200 Comfort V 14 12 2010...
Page 211: ...211 Circuit diagrams TransTig 2500 Comfort...
Page 212: ...212 Circuit diagrams TransTig 3000 Comfort...
Page 213: ...213 Circuit diagrams TransTig 4000 Comfort V 17 12 2012...
Page 214: ......
Page 215: ......