175
EN
Cause:
Overtemperature in the control
circuit
Remedy:
Allow power source to cool down
If the power source is being used with a robot
interface or a field bus
Cause:
Robot not ready
Remedy:
Initialise "Robot ready" signal, ini-
tialise "Source error reset" signal
(N.B. "Source error reset" only
available in conjunction with ROB
5000 and field bus coupler for ro-
bot control)
Cause:
Cooling unit flow watchdog has
been triggered
Remedy:
Check the cooling unit; if neces-
sary, top up the coolant or bleed
the system as described in "Put-
ting the cooling unit into service"
Cause:
The software activation code is
incorrect
Remedy:
Check the software activation
code, try again
Cause:
Phase failure in power supply
Remedy:
Check the mains fuse, the mains
lead and the mains plug
Cause:
Indirect symmetry error
Remedy:
Contact After-Sales Service
Cause:
Mains undervoltage: The mains
voltage has dropped below the
lower limit of the tolerance range
(see section "Technical data")
Remedy:
Check the mains voltage
Summary of Contents for MagicWave 2200 Comfort
Page 2: ...2...
Page 4: ...4...
Page 10: ...10...
Page 23: ...General information...
Page 24: ......
Page 27: ...Control elements and connections...
Page 28: ......
Page 39: ...Installation and commissioning...
Page 40: ......
Page 45: ...Welding...
Page 46: ......
Page 89: ...Setup settings...
Page 90: ......
Page 170: ...170...
Page 171: ...Troubleshooting and maintenance...
Page 172: ......
Page 183: ...183 EN Disposal Dispose of in accordance with the applicable national and local regulations...
Page 184: ...184...
Page 185: ...Appendix...
Page 186: ......
Page 195: ...Spare parts and circuit diagrams...
Page 196: ...196 Spare parts list TransTig MagicWave 2200 Comfort...
Page 197: ...197...
Page 198: ...198 Spare parts list TransTig MagicWave 2500 3000...
Page 200: ...200 Spare parts list TransTig 4000...
Page 201: ...201...
Page 202: ...202 Spare parts list MagicWave 4000...
Page 203: ...203...
Page 204: ...204...
Page 205: ...205 Circuit diagrams MagicWave 2200 Comfort V 12 06 2014...
Page 206: ...206 Circuit diagrams MagicWave 2500 Comfort...
Page 207: ...207 Circuit diagrams MagicWave 3000 Comfort...
Page 208: ...208 Circuit diagrams MagicWave 4000 Comfort V 17 12 2012 1 2...
Page 209: ...209 V 17 12 2012 2 2...
Page 210: ...210 Circuit diagrams TransTig 2200 Comfort V 14 12 2010...
Page 211: ...211 Circuit diagrams TransTig 2500 Comfort...
Page 212: ...212 Circuit diagrams TransTig 3000 Comfort...
Page 213: ...213 Circuit diagrams TransTig 4000 Comfort V 17 12 2012...
Page 214: ......
Page 215: ......