27
EN
Care, maintenance and disposal
General remarks
Under normal operating conditions the MagicCleaner requires only a minimum of care and
maintenance. However, it is indispensable to follow some important points to ensure the
operationality of the machine for many years.
WARNING!
Danger from electric current.
An electric shock can be fatal. Before opening up the machine:
► shift the mains switch into the "O" position
► unplug the machine from the mains
► put up an easy-to-understand warning sign to stop anybody inadvertently switching it
back on again
► using a suitable measuring instrument, check to make sure that electrically charged
components (e.g. capacitors) have been discharged
Every start-up
-
Check mains cable and interconnecting cable for damage
-
Check container and pump for leakage
-
Check whether the allround distance of 0.5 m (1ft. 8in.) is kept to ensure that the cool
-
ing air can easily flow and escape.
NOTE!
Furthermore, air inlets and outlets must in no case be covered, not even covered
partly.
Weekly
Clean device by means of solvent-free products.
Every 6 months
CAUTION!
Danger from pressed air.
Risk of damage to electronic components.
► Clean electronic components from a certain distance only.
Dismantle machine side panels and clean machine inside with dry reduced com
-
pressed air
If a lot of dust has accumulated, clean the cooling-air ducts.
Disposal
Dispose of in accordance with the applicable national and local regulations.
1