49
USB Stick as a Data Logger and for Updating Invert-
er Software
USB stick as a
data logger
A USB stick connected to the USB A socket can act as a data logger for an inverter.
Logging data saved to the USB stick can at any time
-
be imported into the Fronius Solar.access software via the included FLD file,
-
be viewed directly in third-party applications (e.g., Microsoft® Excel) via the included
CSV file.
Older Excel versions (up to Excel 2007) have a row limit of 65536.
Data on the USB
stick
If a USB stick is used as a data logger, three files are automatically created:
-
System file *.sys:
This file saves information from the inverter that is irrelevant to the customer. The file
must not be deleted individually. Only delete all files together (sys, fld, csv).
-
Log file TLxxx_yy.fld (xxx = IG number, yy = a serial 2-digit number):
Log file for reading out data in Fronius Solar.access.
You can find additional information on the Fronius Solar.access Software in the "DAT-
COM Detail" operating instructions at http://www.fronius.com
-
Log file TLxxx_yy.csv (xxx = IG number, yy = a serial 2-digit number):
A log file for reading out data in a spreadsheet program (e.g., Microsoft® Excel)
Summary of Contents for IG-TL 3.0
Page 2: ...0...
Page 4: ...2...
Page 14: ...12...
Page 15: ...General Information...
Page 16: ......
Page 23: ...Installation and Startup...
Page 24: ......
Page 58: ...56...
Page 59: ...Operation...
Page 60: ......
Page 97: ...Troubleshooting and Maintenance...
Page 98: ......
Page 119: ...117 Tightening torque 2 Nm 2 1 5 1 1 1 1 1 1 2 6 1 3 2 ON 7...
Page 124: ...122...
Page 125: ...Appendix...
Page 126: ......
Page 137: ...135...
Page 138: ...136...
Page 139: ...137...