![Fronius IG-TL 3.0 Operating Instructions Manual Download Page 101](http://html1.mh-extra.com/html/fronius/ig-tl-3-0/ig-tl-3-0_operating-instructions-manual_2339183101.webp)
99
Class 3 status
codes
Class 3 comprises status codes that may appear during feed-in operation and that do not
cause a permanent interruption of the operation of feeding power into the grid.
After automatic disconnection from the grid and waiting for its conditions to return to those
stipulated, your inverter will try to resume feed-in operation.
Description
Grid conditions are thoroughly tested, and as soon as they are
again within the permissible range, the inverter will resume
feeding power into the grid.
Remedy
Check grid connections or fuses.
If this status code keeps recurring, contact your system install-
er.
301
Overcurrent (AC)
Description
A short interruption of power feeding into the grid due to over-
current in the inverter circuit.
The inverter returns to the startup phase.
Remedy
The fault is rectified automatically.
If this status code keeps recurring, contact your system install-
er.
302
Overcurrent (DC)
Description
Description A short interruption of power feeding into the grid
due to overcurrent in the inverter DC circuit.
The inverter returns to the startup phase.
Remedy
The fault is rectified automatically.
If this status code keeps recurring, contact your system install-
er.
303
Over-temperature cooling element
Description
Short interruption of power feeding into the grid due to over-
temperature.
The inverter returns to the startup phase.
Remedy
The fault is rectified automatically.
If this status code keeps recurring, contact your system install-
er.
304
Interior temperature too high
Description
Short interruption of power feeding into the grid due to over-
temperature.
The inverter returns to the startup phase.
Summary of Contents for IG-TL 3.0
Page 2: ...0...
Page 4: ...2...
Page 14: ...12...
Page 15: ...General Information...
Page 16: ......
Page 23: ...Installation and Startup...
Page 24: ......
Page 58: ...56...
Page 59: ...Operation...
Page 60: ......
Page 97: ...Troubleshooting and Maintenance...
Page 98: ......
Page 119: ...117 Tightening torque 2 Nm 2 1 5 1 1 1 1 1 1 2 6 1 3 2 ON 7...
Page 124: ...122...
Page 125: ...Appendix...
Page 126: ......
Page 137: ...135...
Page 138: ...136...
Page 139: ...137...