69
EN-US
DAT COM
Indicates status of data transmission, re-
sets the Personal Display Card and Interfa-
ce Card
OK COM / ERROR COM
Displays data communication available via Solar Net or an error that occurred in data com-
munication
PDCD RST
Resets the Fronius Personal Display Card option
IFCD RST
Resets the Fronius Interface Card option
TIME
Date and time setting
STATE PS
Status display of power stage sets; the last
error that has occurred can be displayed
IMPORTANT!
Each inverter must be assigned its own address when connecting several
inverters in a data communications system.
Setting range
Displays OK COM or ERROR COM;
PDCD RST / IFCD RST
Unit
DDMMYYYY, HH:MM
Setting range
Date / Time
Factory setting
-
IMPORTANT!
The "TIME" menu item is only supported when the Fronius Datalogger op-
tion is installed.
IMPORTANT!
Due to the low level of irradiance early in the morning and in the evening,
the status codes 306 (power low) and 307 (DC low) are displayed routinely at these times
of day. These status messages do not indicate any kind of fault.