28
Potential Equali-
zation
A permanent potential equalization must be established between the HyLOG Fleet system
and the vehicle chassis. The total resistance between the HyLOG Fleet system and the hall
floor should not exceed 25 MOhm. There are 2 possibilities for connecting the device to
the vehicle chassis.
1.
Use the grounding contact at the power interface (AUX-contact)
2.
Assembly of the control panel (display) on the metal chassis, using a screw connec-
tion, which ensures a permanent electrical connection of the display housing to the ve-
hicle chassis.
Application ex-
ample for the ve-
hicle connection
not connected
1
S1
S2
K1
K2
U1
2
3
4
5
6
7
8
9
10
11
12
CAN-GND
CANH
CANL
Akku_EN-
Input+
Input-
OUT1+
OUT1-
OUT2+
OUT2-