41
EN
Technical data
HyLOG Fleet
24015F
Input data
Fuel (ISO 14687-2 / SAE J2719)
Hydrogen 5.0
(3.0 available on request)
Tank capacity, mass and nominal pressure of the hydro-
gen contained
27 litres, 0.6 kg, 350 bar
7.13 gal., 1.32 lb., 5074.55 psi.
Air inlet
< 600 m
3
/h
< 21188.8 cfh
Fuelling protocol
SAE J2601-3
Maximum filling rate
see fuelling guideline
Fuel cell data
DC continuous output
1.8 kW
System voltage
25.6 V DC
Fuse protection of the power interface
250 A, 500 A short-term
System efficiency
> 47%
Data relating to the integrated back-up battery
High-performance nickel-metal hydride battery
NiMH
Rated operating voltage
25.6 V DC
Nominal capacity
approx. 30 Ah
Output data
Concentration of hydrogen in the process exhaust air
< 25% of the lower explosive
limit LEL
Air outlet
< 600 m³/h at max. 65 °C
< 21188.8 cfh at max. 149 °F
Reaction condensate (purified water, fully desalinated) < 3.2 litres per tank
< .85 gal. per tank
Guidelines
2014/68/EU
Pressure equipment guideline
2014/30/EU
EMV guideline