It is forbidden to duplicate this manual or parts of it in any way or any form without written permission of the author © 2003
FS 270 series
FROMM
THE MACHINE DOES NOT STOP WHEN THE EMERGENCY MUSHROOM-HEAD BUTTON IS
PRESSED
The arrised problem
Possible remidies
- emergency circuit failure
- Check the circuit
- emergency mushroom-head button not working
-
Replace the emergency mushroom-
head button
Should the problem persist, contact the Customer After-Sales Service of MANUFACTURER
THE TURNS AT THE BOTTOM AND AT THE TOP OF THE LOAD ARE NOT REGULATED
PROPERLY
The arrised problem
Possible remidies
- limit switches (
1
) not connected properly
- Check the wiring
- limit switch malfunctioning
- Replace the limit switch
-The control card (
2
) is not working properly
- Replace the faulty card by carefully
referring to the wiring diagram attached to
the machine documentation
Should the problem persist, contact the Customer After-Sales Service of MANUFACTURER
ALARMS AND E
R
RORS
1
2
29