AL 3 INVERTER FAULT
The arrised problem
Possible remidies
- This alarm signals the blocking of an inverter
- Turn off the machine. Wait 20 seconds and
turn it on again.
If the problem persists:
- Check the situation on the display of the
inverter referring to the inverter instruction
manual that is enclosed with the machine
documentation
- Check for the presence of mechanical
motor locks, if any, and proceed as
required
- Inverter not working properly
-
Replace the inverter
Should the problem persist, contact the Customer After-Sales Service of MANUFACTURER
Al 4 TRANSPALLET
The arrised problem
Possible remidies
- Phonic wheel sensor incorrectly positioned
- Check for the correct positioning of the
sensor as compared to the phonic wheel
The distance should not be more than 2mm
- Check for the correct connection of the
sensor by means of the associated
connector
- Sensor not connected properly
- Replace the sensor
Should the problem persist, contact the Customer After-Sales Service of MANUFACTURER