It is forbidden to duplicate this manual or parts of it in any way or any form without written permission of the author © 2003
FS 270 series
FROMM
ELECTRICAL CABINET
Figure 12
1 = Table rotation inverter
2 = Carriage inverter
3 = Pre-stretching inverter
( Kit 62.8242 )
4 = Feeder
5 = Control card
ATTENTION!
After the fist installation
Follow procedure below before starting the machine
-
Control if the emergency button is free
-
Turn on the machine
-
Wait 5 seconds and than make the first rotation in manual mode
-
If the turntable rotates, follow procedure below
After installation or maintenance of the machine follow procedure below to check the efficiency of the
safetydevices, such as:
9
Interlocking of the crush-proof interlocked operator guard
9
Emergency button
Check for the efficiency of the mobile interlocked crush-proof guard of the carriage
- start the machine
- trigger the interlocked operator guard
Check that the carriage inverts its running direction for approximately 3 seconds and that the
turnplate starts slowing down and stops within a few seconds
Check for the efficiency of the mushroom-head button (Emergency stop)
- start the machine
- press the emergency mushroom-head button
Check that the machine stops within a few fractions of a second
1
ASS
E
MBL
Y
SEQUE
NCE
2
3
4
5
21