2 Installation
❒ Run the bus cable through the large grommet
❒ Fit the holding frame as shown at the desired position in the room using the
anchors and screws provided
➥ The large grommet must be on the right!
➥ It is recommended to install the device above a flush-mounted socket so that
there is plenty of space to stow away the bus cable.
2.1 Initial start-up
NOTICE
You should have the initial startup carried out by the authorised heating engineer
from Froling customer services.
2.1.1 Connecting the bus cable
For the bus connections between the individual modules, cable type
LIYCY paired 2x2x0.5 should be used. The connection to the 5-pin plugs should be
carried out according to the following diagram:
+U
BUS
CAN H
CAN L
+U
BUS
CAN H
CAN L
Braided shield
White
Green
Yellow
Brown
Braided shield
White
Green
Yellow
Brown