5.2 Water
5.2.1 Water - Status
System menu
Water
DHW tank top temperature
58°C
Current temperature of the DHW tank. The DHW tank is heated when the time window for the DHW tank load‐
ing is reached and the current temperature of the DHW tank has fallen below the value using the parameter
“Reload if DHW tank temperature is below”
. A loading of the DHW tank takes place when either
the time window has elapsed or the temperature value which is set under “
Set DHW temperature”
is
reached.
DHW tank bottom temperature
55°C
Prerequisite: Solar panel system is regulated by Froling!
Current temperature in the area of the reference sensor of the solar panel system.
DHW tank pump control
0%
Specifies the speed of the DHW tank pump as a percentage of maximum speed.
5
Menu overview and parameters
Water
20