5.6.20 Fitting the compressed air cleaner (optional)
The compressed air cleaner is fitted to the stop side of the reversing chamber door. The
following steps show how to fit it to the right-hand side of the boiler. The procedure for
fitting it to the left-hand side is the same, just on the opposite side. The brackets have
already been fitted in front of the side panels.
r
Fit the compressed air tank to the brackets.
r
Fit the elbow (1) and hose connection (2) to the compressed air tank.
r
Fit the double nipple (3), taper (4), elbow (1) and hose connection (2) to the right-hand
side of the reversing chamber door on the air distribution frame.
r
Fit the hose (6) between the compressed air tank and air distribution frame to the hose
connection using hose clamps (5).
r
Fit the control boxes (7) at a suitable place on the boiler.