Installation | 5
M2050222_en | Installation instructions Lambdamat LM 1500 KOM
35
5.6.11 Fitting the door contact switch
Before fitting the insulation panels, check that the tunnel door and the combustion
chamber door are tight as explained below.
r
Open the door.
r
Insert a sheet of paper at both the top and the bottom between the door and the boiler.
r
Close the door.
r
Try to pull out the sheet of paper.
Ä
If the paper cannot be removed:
door is tightly sealed.
Ä
If the paper can be removed:
door is not sealed – adjust the closing mechanism.
Adjusting the seal:
r
Undo the lock nut (A).
r
Adjust the closing force by turning the top nut (B).
The following steps explain how to fit the door switch to the top tunnel door; fit the fittings
to the bottom combustion chamber door in the same way.
r
Fit the door frame (A).
r
Undo the two screws on the door handle and remove the handle.
r
Undo the cap nuts (B) on the four assembly screws.
r
Insert the insulation sheet at the handles and fit with lock nuts.
r
Secure the insulation sheet with cap nuts.
r
Replace the door handle.