5.9 Installing the electrostatic precipitator system on Turbomat TM
If the electrostatic precipitator system is retrofitted to an existing Turbomat, the flue
gas recirculation must be modified. The modification work is carried out according to
the enclosed instructions of the modification set.
Flue gas recirculation before modification
Exhaust gas recirculation after modification
The electrostatic precipitator system is placed between the boiler and the induced
draught. The piping must be provided by the customer in compliance with the
recommended distances and the installation plan. The pipeline must be as short as
possible and insulated with suitable thermal insulation.
Connections:
▪ A – Lower flue gas connection: Raw gas inlet (pipe from boiler)
▪ B – Upper flue gas connection: Clean gas outlet (pipe to the induced draught)
Assembly
5
Installing the electrostatic precipitator system on Turbomat TM
Installation and Operating Instructions EF 250-500 | M2140120_en
31