background image

!

Do not use with water that is microbiologically unsafe or of unknown quality 
without adequate disinfection.
Testing was performed under standard laboratory conditions, actual 
performance may vary.
For cold water use only.
This filter must be protected from freezing, which can cause cracking of the
 filter and water leakage.
Do not allow children under 3 years of age to have access to small parts 
during installation.
The installation must comply with all applicable state and local regulations.

4. Installation Tips

5. Installation Steps
     Precautions: 

 How to cut the tubing?

Please cut the tubing into two sections in proper length, make sure cut
them squarely and cleanly.

 How to drill a hole on my sink (Optional)

     Note

Please remember to wear safety glasses to protect your 

                  eyes before proceeding.
     Use a metal bit to drill. The recommended diameter of the hole is 1.2"

 How to connect/disconnect the tubing?
 
To connect: please push the tubing into the fitting and make sure it is fully
 inserted. Then put the blue lock clip on the fitting, it will lock the tubing in
 place.
To disconnect: please remove the blue lock clip from the fitting, push in the 
lock sleeve, and then pull out the tube from the fitting 
Note: If the tubing is not fully inserted, water leakage may occur. Pulling 
out the tubing directly will damage the fitting, which may also cause water
leakage.

FRIZZLIFE INC.

www.frizzlife.com

Page 3

0.5 inch

.5

Press

Remove

Remove
blue clip

Model: PD1000-TAM4

Summary of Contents for PD1000-TAM4

Page 1: ...Model PD1000 TAM4 OWNER S MANUAL ...

Page 2: ... 4 INSTALLATION TIPS 3 5 INSTALLATION STEPS 3 6 FIRST TIME USAGE 9 7 USER INTERFACE 9 8 REPLACEMENT OF FILTER CARTRIDGE 11 9 FILTER REPLACEMENT INSTRUCTION 12 10 MAINTENANCE 13 11 TROUBLE SHOOTING 14 12 FREQUENTLY ASKED QUESTIONS 16 13 LIMITED PRODUCT WARRANTY 17 CONTENT ...

Page 3: ...ife PD1000 TAM4 reverse osmosis undersink filter system with 1000G RO membrane If you have any questions or need any assistance please contact support frizzlife com Find the installation video Register to get 150 warranty INSTALLATION INSTRUCTION FRIZZLIFE INC www frizzlife com Page1 1 Email us your order ID and full name at support frizzlife com 2 Scan the QR code to register Model Min 39ºF Max 1...

Page 4: ...IZZLIFE INC www frizzlife com Page 2 PD1000 ASR411 CP filter OUT TDS Filter life Flush button Filter life reset TAM4 ASR412 RO filter Power supply Connect to water supply Connect to drain pipe Connect to drinking faucet Do not use this plug Model PD1000 TAM4 ...

Page 5: ...gth make sure cut them squarely and cleanly How to drill a hole on my sink Optional Note Please remember to wear safety glasses to protect your eyes before proceeding Use a metal bit to drill The recommended diameter of the hole is 1 2 How to connect disconnect the tubing To connect please push the tubing into the fitting and make sure it is fully inserted Then put the blue lock clip on the fittin...

Page 6: ...anly Fig 1 Put one end of the tubing into boiled water for 5 seconds to soften itself Fig 2 Load the 3 8 tubing through the nut Fig 3 Connect the end of 3 8 tubing that has been softened into the 3 way feed water valve Make sure push and squeeze the tubing to the very end Fig 4 Use a wrench to tighten the nut please do not over tighten Fig 5 Step 1 Cut and Soften the 3 8 tubing Step 2 Connect thre...

Page 7: ...Fig 9 Valve installation complete Remove all the plugs by pressing the fitting sleeves Fig 10 Connect the other end of 3 8 tubing into Supply port on the back of the system make sure to insert the tubing about 0 8 inch to the end of the fitting Fig 11 Put the lock clip on the fitting to secure the connection Fig 12 Step 3 Connect the water supply COLD WATER ONLY Step 4 Connect the SUPPLY water tub...

Page 8: ...a 1 4 hole in the drain pipe Make sure not to penetrate the opposite side of the pipe Fig 15 Mount the drain saddle and tighten the screws with a screw driver Fig 16 Insert the 1 4 tubing to the drain saddle about 1 4 and lock the fitting with a blue clip Fig 17 Step 5 Install the drain saddle FRIZZLIFE INC www frizzlife com Page 6 Fig 18 Fig 19 Insert the other end of 1 4 tubing into the Waste po...

Page 9: ...ur counter top or granite does not have an existing hole please drill one 1 2 before proceeding Remove the small blue clip on the INLET end and connect the 1 4 tubing on it make sure it hits the bottom of the fittings Fig 21 Put back and lock the blue clip Fig 22 Cut a 1 4 tubing again Connect the OUTLET end with another 1 4 tubing in the same way Fig 23 Follow the steps below and mount the faucet...

Page 10: ... then connect the power supply Turn on the angle valve and 3 way feed water valve Check for leaks Fig 33 Insert the DC head of the power adapter into the POWER port on the back of the system Fig 34 Step 10 Connect the power cord Fig 24 Fig 25 Fig 26 Fig 27 Fig 29 Fig 30 Fig 31 Fig 32 Fig 28 Model PD1000 TAM4 ...

Page 11: ... malfunction Fig 35 Fig 36 Note When the system keeps producing water continuously for 30 minutes the system will enter into protection status and all the components stop working The indicators will flash in red In this condition please unplug the power for 10 seconds and then power on again The system will automatically flush for 30 seconds after the power supply is plugged 7 User Interface FRIZZ...

Page 12: ...ilter life indicator Different colors suggest different remaining lifespan A Indicator constant lit in white the filter is normally working B Indicator flashed in red the filter lifetime is about to be expired remaining lifespan 5 C Indicator constant lit in red the filter is expired Long time operation reminder When the system keeps producing water continuously for 30 minutes the system will ente...

Page 13: ...ars or cumulative water production for 120 hours around 1800 2000gal around 900 1000gal Model Number ASR411 ASR412 1000G TAM4 Filter PP CB 2 in 1 filter RO membrane Alkaline remineralization filter 1st stage 2nd stage 3rd stage Model PD1000 TAM4 Filter Life Reset Select filter when the system is powered on long press the Reset for 3 seconds the buzzer will beep and you can start to select the filt...

Page 14: ...Screw the new cartridge clockwise into the system 9 Filter Replacement Instruction FRIZZLIFE INC www frizzlife com Page 12 If you are going to replace TAM4 filter You don t need to cut off the water supply since it adopts auto shut off design Twist the housing counter clockwise and use a wrench to unscrew the housing body Fig 42 Use a wrench to unscrew the housing body Fig 43 Take out the old cart...

Page 15: ...ter for at least 10 minutes before next time usage C If the system will be not used for a long time please cut off the water supply cut off the power and turn on the handle of the faucet to release the internal pressure and avoid damage to the system 10 Maintenance Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection Model PD1000 TAM4 Long pres...

Page 16: ...sible Cause The system is not connected to the power adapter or the connection is loose Cold water valve 3 way feed water valve or the faucet is off Lifetime of the filter cartridge is expired Connection of pipeline is incorrect No water out of faucet Please replace the filter according to the instruction Please contact customer service team Please check PE pipes Filter is blocked Water pressure i...

Page 17: ...lter cartridge is expired Please discharge water for 5 minutes before usage The system has been off work for more than 2 days Please ensure the water source is municipally treated water or has been properly disinfected prior use Quality of feed water is too bad Filtered water in poor quality Please reinstall the system according to the instruction or contact customer service team Pipes or filters ...

Page 18: ...e of air is released So you will see a huge number of bubbles in the water It looks cloudy and white but they are just bubbles After you put the water still for a while all bubbles will be gone the water is totally good for drinking Osmosis is a natural phenomenon happens in all RO system no matter if you have a conventional RO system or tankless RO system When the RO system starts to work pressur...

Page 19: ...r To be free of defects in material and workmanship by Frizzlife INC Frizzlife will replace or repair components of the unit that Frizzlife has deemed to be broken within the limits of the warranty without charge The customer is not responsible for any freight involved with shipping the item back for inspection and shipment of replacement items Frizzlife is not liable for cost of removal installat...

Page 20: ...50 Extended Warranty 1 Email us your order ID and full name at support frizzlife com 2 Scan the QR code below to register Most of the unit components are made of plastic and eventually can break or crack from stress There are no other warranties which extend beyond what is described above 2 Filter Cartridges are considered as disposable items thus are not covered by warranty 3 Customer is responsi...

Reviews: