35
2.7 Enabling the Docking Station Option
Press the ‘GO’ button and the following will be displayed:
2.8 Testing the Docking Station and Perimeter Wire Position for Docking
It is best to test the position of the Docking Station and to determine if any small adjustments need to be
made before driving the rest of the stakes into place. Position the Robomow towards the perimeter wire, at
least 10 feet (3m) before the Docking Station to allow the mower to stabilize itself on the wire. See figure
2.12.
Confirm that the perimeter wire leading to the Docking Station is fastened to the ground. Securely
peg if necessary.
Insert the Manual Controller back into the holder and pivot down flush.
Confirm the ‘On’ led is blinking on the Docking Station Operation Panel.
Press the upper scroll arrow on the Manual Controller once for the message
‘Go to dock’
to
display and then press GO.
Follow the Robomow and confirm that it docks properly into the Docking Station. This is done by
insuring the two metal contacts on the front of the Robomow make full contact with the metal
contact plate located under the cover of the Docking Station. If necessary, slightly move the
Docking Station so that the Robomow meets these contacts as centered as possible.
Once the test is completed and you are satisfied with the Docking Station position, finish driving
the 5 stakes securing the Docking Station into the ground.
Press ‘GO’ to confirm ‘ON’ setting
Press ‘GO’ and scroll to display ‘ON’
Enable Dock ON
Press GO
Enable Dock ON
Confirm
Figure 2.11 – Enabling Docking Function
Figure 2.12– Testing Docking Station Setup
Min. 10 feet (3m)