13
- Thoroughly remove any existing deposits.
- Protect plug from contamination, replace if
necessary.
- Check fusion plug and contact sockets of the
fitting for dirt before connecting.
3.
Basic “Fusion” Procedure
3.1
Preparation
The appropriate assembly instructions need to be
observed for the correct processing of FRIALEN
®
safety fittings and FRIAFIT
®
sewage system. The
same applies for fittings by other manufacturers.
IMPORTANT!
Roll out cables completely!
This applies to power cable, fusion cable, and
extension cable if required. The contact sur-
faces of the fitting and the fusion plugs must be
clean; dirty contacts can cause overheating and
charring of the plug. If necessary carefully re-
move any existing deposits.
Always protect plugs from contamination. If
there is evidence of a deposit which cannot be
completely removed, the fusion plugs must be
replaced.
- Prepare fitting and pipes for fusion in accordance
with assembly instructions.
- Ensure that the contact pins on the fitting are
accessible for connection of fusion plugs.
- Connect to power supply (mains or generator).
- If using a generator, start it first and leave to warm
up for 30 seconds.
- Switch on unit by the main switch.
- Connect fusion plug with contact pins of the
fitting.
FT_2377e_II_07_GB.qxd 13.02.2007 12:31 Uhr Seite 13