8
1.7 Emissions
The (equivalent) continuous sound pressure level of
all FRIAMAT
®
fusion units is less than 70 db(A). When
working in a quiet environment, the signal when set to
“loud” comes across as very loud. For this reason it is
possible to adjust the signal (loud/quiet).
1.8
Safety precautions on site
WARNING!
FRIAMAT
®
fusion units are splash water proofed.
They may however not be immersed in water.
1.9
Signal equipment
FRIAMAT
®
fusion units confirm certain operating
procedures using a signal (1, 2, 3 or 5 signal
sounds). The signals signify the following:
1 signal:
reading in of barcode confirmed.
2 signals: fusion process completed.
3 signals: supply voltage too low / too high.
5 signals: warning: error, refer to display!
1.10
Emergencies
In case of an emergency switch off main switch
immediately to the “OFF” position and disconnect
your FRIAMAT
®
-model from the power supply.
FRIAMAT
®
fusion units can be shut off by:
- activation of main switch or pulling out the power
supply plug.
2. Basic
Data
2.1
Design/parts
All electronic parts of your FRIAMAT
®
-model are
kept in a splash water proofed casing. A receptacle
for the fusion and mains cable is situated at the
back. At the top there is an accessory box; at the
right side is the interface box.
FRIAMAT
®
fusion units are designed for a maximum
fusion voltage of 48 V. A safety transformer sepa-
rates supply and fusion voltage.
FT_2377e_II_07_GB.qxd 13.02.2007 12:31 Uhr Seite 8