background image

8

1.7 Emissions

The (equivalent) continuous sound pressure level of
all FRIAMAT

®

fusion units is less than 70 db(A). When

working in a quiet environment, the signal when set to
“loud” comes across as very loud. For this reason it is
possible to adjust the signal (loud/quiet).

1.8

Safety precautions on site

WARNING!

FRIAMAT

®

fusion units are splash water proofed.

They may however not be immersed in water.

1.9

Signal equipment

FRIAMAT

®

fusion units confirm certain operating

procedures using a signal (1, 2, 3 or 5 signal
sounds). The signals signify the following:

1 signal: 

reading in of barcode confirmed.

2 signals:  fusion process completed.
3 signals:  supply voltage too low / too high.
5 signals:  warning: error, refer to display!

1.10

Emergencies

In case of an emergency switch off main switch
immediately to the “OFF” position and disconnect
your FRIAMAT

®

-model from the power supply.

FRIAMAT

®

fusion units can be shut off by:

- activation of main switch or pulling out the power

supply plug.

2. Basic 

Data

2.1

Design/parts

All electronic parts of your FRIAMAT

®

-model are

kept in a splash water proofed casing. A receptacle
for the fusion and mains cable is situated at the
back. At the top there is an accessory box; at the
right side is the interface box.

FRIAMAT

®

fusion units are designed for a maximum

fusion voltage of 48 V. A safety transformer sepa-
rates supply and fusion voltage.

  FT_2377e_II_07_GB.qxd  13.02.2007  12:31 Uhr  Seite 8

Summary of Contents for FRIAMAT BASIC ECO

Page 1: ...Operating Instructions FRIAMAT FRIAMAT FRIAMAT...

Page 2: ...ng up connecting 12 2 6 Operating 12 3 Basic Fusion Procedure 13 3 1 Preparation 13 3 2 Enter barcode 14 3 3 Starting fusion process 15 4 FRIAMAT basic eco 16 4 1 Description of function buttons 16 4...

Page 3: ...s 30 5 9 1 3 Continuous number and Seam number 31 5 9 1 4 GPS 1 3 31 5 9 2 Traceability barcodes Pipe number Pipe length 31 5 9 3 Info text Comment 1 Comment 2 Subcontractor 33 5 9 4 Scraper tool 33 6...

Page 4: ...o dangers with regard to the health of the user your FRIAMAT model or other material goods of the operator the efficient operation of your FRIAMAT model Everybody involved with operating servicing and...

Page 5: ...0 08 94 The designated use also includes observation of all the advice in these operating instructions as well as the guidelines by DVGW Standards DVS UVV and local directives IMPORTANT Any other use...

Page 6: ...ables Check connection cable for any damage Pull out the plug prior to any maintenance or service tasks Allow any service and repairs to be carried out only at authorised service stations Connect fusi...

Page 7: ...voltage of your FRIAMAT model before starting the fusion process Your FRIAMAT model has been designed for input voltage of 190 250 volt When using an extension cable please ensure sufficient cross se...

Page 8: ...de confirmed 2 signals fusion process completed 3 signals supply voltage too low too high 5 signals warning error refer to display 1 10 Emergencies In case of an emergency switch off main switch immed...

Page 9: ...continuously measures the ambient temperature WARNING The temperature sensor for determining the ambient temperature is attached to the fusion cable at the reader wand cable near the reader wand pouch...

Page 10: ...ay Connection Plug 4 0 mm Hand scraper replacement blades Manual emergency programming Remote operating pass Operator pass Supervisor pass FRIATRACE from version 5 1 FRIATEC Memory Stick FRIATEC Memor...

Page 11: ...g 19 kg Code 2 5 interleaved Code 2 5 interleaved Code 128 20 C 50 C 20 C 50 C Short Circuit and Short Circuit and Cut Off Cut Off USB no serial serial no no yes yes optional optional yes yes optional...

Page 12: ...operated outdoors if protected from rain and wet Set up your FRIAMAT model on level ground preferably horizontal Ensure that generator is fused with a 16 A mini mum slow acting fuse Plug unit connect...

Page 13: ...required The contact sur faces of the fitting and the fusion plugs must be clean dirty contacts can cause overheating and charring of the plug If necessary carefully re move any existing deposits Alwa...

Page 14: ...ensure that the fusion plugs of your FRIAMAT model are attached to the contact pins on the fit ting across the entire internal contact width Once the barcode label has been attached to the fitting thi...

Page 15: ...operating instructions by the appropriate fitting manufacturer Operating steps 1 Display shows PIPE PREPARED confirm if correct 2 Press the START button to start the fusion process Now an automatic ch...

Page 16: ...cess without saving data If you keep the STOP button pressed for a longer period regardless in which submenu you are navigating you will return to the main screen CODE Arrow buttons The arrow buttons...

Page 17: ...al menus Time Date Language Volume Use the arrow buttons to take you to the required individual menu and select this using the START button Within the individual menus you can make the desired changes...

Page 18: ...sing the START button Within this individual menu you can access the information you requested and leave each menu by pressing either the START or the STOP button 4 5 Menu Emergency input By pressing...

Page 19: ...n inputting process without saving it If you keep the STOP button pressed for a longer period regardless in which submenu you are navigating you will return to the main screen CODE Arrow buttons The a...

Page 20: ...g Temperature Unit number Software version Service date 5 2 Menu Layout 1 appears only if traceability is switched on and or there is data 2 appears only if documentation is switched on 3 appears only...

Page 21: ...ommission number Time Operator pass3 Date Transmit Info text Language Volume All Comment 1 Selection Comment 2 Delete Subcontractor All Traceability Selection Pipe number1 Pipe length1 GPS data Seam n...

Page 22: ...enu Documentation By activating the appropriate guide buttons it is possible in this menu to switch documentation on or off 5 3 2 Time The guide button MENU will take you to the menu Basic settings wi...

Page 23: ...ce is activated and thus visible to you when the documentation has been switched on All submenus are not activated on delivery factory setting as a point of principle Press the MENU button to select t...

Page 24: ...s up down you will be given an overview of the settings that have been selected on your FRIAMAT model Press the STOP but ton to exit this submenu IMPORTANT By means of the operator pass your FRIAMAT m...

Page 25: ...tor Activating switching on this menu will allow you to include additional text information to a fusion process 5 4 7 Traceability The guide button Menu will take you to the menu Fusion sequence The s...

Page 26: ...Activating switching on this menu will allow you to enter data e g unit number of the scraper tool used for the preparation of the fusion For this facility the scraper tool must have an appropriate ba...

Page 27: ...f you confirm SELECTION using the START button you will be able to select from indivi dual commission numbers During the data transfer the fusion unit will display the text TRANSFERRING PLEASE WAIT an...

Page 28: ...y temperature ambient temperature unit number software version and date of next service Make sure you have this information with you when you approach an authorised FRIATEC service station with questi...

Page 29: ...message ERROR 91 on your FRIAMAT Formatting to FAT 12 or FAT 16 can be done in sub menu Formatting Press the MENU button to access the main menu Use the arrow buttons up down to access submenu Formatt...

Page 30: ...umber and the STOP button to exit the submenu If you have already entered one or several commis sion numbers you will be able to choose in ID Data in submenu Commission number between CHANGE changing...

Page 31: ...the START button and use the arrow buttons up down to access the screen where you are able to enter the coordinates of the fusion processes carried out by you GPS 1 GPS 2 and GPS 3 Symbols are chosen...

Page 32: ...see also Section 5 9 4 You will access the start mode the upper line in the display will show the connected fitting to be fused the lower line will ask START IMPORTANT At this point you will be able t...

Page 33: ...it again to continue preparing for your fusion IMPORTANT The additional text must be newly entered for each fusion process as no text will appear in the report otherwise If the START button is activa...

Page 34: ...d service stations in section 8 2 Please include all connecting adapters for service checks WHAT WHEN WHO Cleaning the reader wand and checking for damage daily User Checking function weekly User Clea...

Page 35: ...it cool down As the power consumption of different electrofusion fittings will vary there may be the option of fusing a different fitting 7 3 Fusion interruption If the fusion is interrupted because e...

Page 36: ...fitting winding of send in fitting for checks 05 Fitting winding Current flow Check open circuit interrupted connection of fusion plug on fitting If okay replace the fitting and send in for checks 06...

Page 37: ...ing Power con Please contact exceeded sumption FRIATEC of fitting service hotline exceeds 49 0 621 rating of the 486 1533 FRIAMAT 23 Generator Generator Please contact failure maybe not FRIATEC suited...

Page 38: ...barcode first of the fitting was accidentally read in Please read in Only with prime eco valid operator pass this appears when the operator pass needs to be read in e g when a unit is blocked and or a...

Page 39: ...n completed Voltage V Readjust generator and Frequency Hz confirm by pressing STOP button Memory empty Only with prime eco printing out not possible if memory is empty Memory full Only with prime eco...

Page 40: ...es These technical statements are checked regularly in terms of up to dateness The date of the recent revision is specified on the document Visit www friatools de in the left navigation menu you will...

Page 41: ...41...

Page 42: ...42...

Page 43: ...43...

Page 44: ...IATEC Aktiengesellschaft Technical Plastics Division P O Box 71 02 61 D 68222 Mannheim Phone 49 621 486 1533 Fax 49 621 479196 www friatools de info friatools friatec de 2377e 1 II 07 wdw Stand 27 10...

Reviews: