Following installation, check to confirm that, when the appliance is moved to
the limits of the tether in
each direction, no stress is transmitted to the electrical
conduit.
For STG7-P-GAS only:If the oven is to be installed with casters, the installation shall
be made with a connector complying to the Standard for Connectors for Movable Gas
Appliances ANSI-Z21.69 (latest edition), and a quick-disconnect device that complies
with the Standard for Disconnect Devices for Use with Gas Fuel, ANSI-Z21.41 (latest
edition).Provide a gas line strain relief to limit the movement of the oven without
depending on the connector and the quick-disconnect device or its associated piping
to limit oven movement.
If it is necessary to disconnect the restraint, first turn off the gas supply.
Reconnect the restraint before turning the gas supply on and returning the
oven to its original installation position.
Following installation, check to confirm that, when the appliance is moved to
the limits of the tether in each direction, no stress is transmitted to the piping of
the gas supply.
Note:
Units may be delivered completely stacked or placed on a base.
1.4 INSTALLATION CODES AND STANDARDS
In the United States, all STG series ovens and STW series warmers or combinations
must be installed according to the following codes:
State and local codes.
National Electric Code, ANSI/NFPA 70 (latest edition). available from National
Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02269.
National Fuel Gas Code, ANSI-Z223.1/NFPA 54 (latest edition), available from
National Fire Protection Association,1 Batterymarch Park, Quincy, MA 02269.
ANSI/NFPA 96, ”
Standard for Ventilation Control and Fire Protection of
Commercial Cooking Operations” (latest edition), available from National Fire
Protection Association, 1 Batterymarch Park, Quincy, MA 02269.
In Canada, all STG series ovens and STW series Warmers or combinations must be
installed according to the following codes:
Local codes.
Canadian Electric Code, CSA C22.1 (latest edition) available from the
Canadian Standard Association, 178 Rexdale Boulevard, Toronto, Ontario,
CANADA, M9W 1R3