Technical Description
A 52/73
STUN-E512_E3__EN.DOCX
www.freund-germany.com
3 Technical
Description
The Electric-Stunner STUN-E512
was built in accordance with the German Animal Protection Slaughter
Regulation from 01.01.2013 (TierSchlV) and the EC-Regulation
1099/2009.
was built according to the state of the art and complies with the general
safety and health requirements of the European Union.
is operationally safe, assuming compliance with the operating manual,
the company-specific instructions and the accident prevention
regulations.
Features
7 pre-installed stunning programs, individually adaptable for different
species and sizes of animals
Selectable head and heart stunning programs
Acoustic buzzer for minimum stunning time
Visual and acoustic stunning error display
LED display
Better meat quality and higher yield due to fewer blood spots and
bone fractures
Integrated interface for data recording
Optional external data memory STUN-EMEM01 stores data for up to
6000 stuns:
o
Electric current reached within first second?
o
Minimum stun time (4 s) maintained at minimum current in
coulombs (separately for head and heart)?
o
Error Yes/No for each measured parameter
3.1 Working
method
of the electric-stunner
A stunning plant consists of the electric-stunner STUN-E512 and a stun-
tong.
Body resistance
animal
The electric-stunner works according to the constant current measurement
process.
The body resistance of the animal (pig, sheep or goat) is thus continuously
measured at short intervals and analysed based on the resistance
measurement principle. If the measured value is within the pre-set range of
up to 1400 ohms, the stun voltage is automatically switched on.
Body resistance
humans
The body resistance of humans is significantly higher than the body
resistance of the animals being slaughtered. If the pre-set resistance of
1400 ohms is exceeded, the electric stunner switches off the stun voltage
to protect the operating personnel. Danger to persons is averted due to the
large difference in switch-on value.
If the resistance drops below the minimum value, an electronic fuse is
triggered to prevent damage to components.