50
Cyclone PRO User Manual
CYCLONE PRO
2) Blank Check Module
3) Program Module
4) Verify Module.
When the Start Button is pressed, the “Target Power On” LED will turn on,
indicating that the Cyclone PRO is powering up the target board.
Then the Standby LED will turn off and the Security LED will turn on. Here, if
the target flash needs to be erased first to bypass the security, the Security
LED will turn off and the Erasing LED will turn on.
When the Erasing LED turns off, the Cyclone PRO attempts to pass security
again.
Then, when the Cyclone PRO starts programming the module, the
“Programming” LED is illuminated.
After this is done, the “Programming” LED is turned off and the “Verifying”
LED is turned on, designating that the Cyclone PRO is verifying the contents
just programmed into the target.
Finally, if these operations have been performed successfully, the “Success”
LED and the “Standby” LED are illuminated. One stand-alone programming
cycle has just been completed.
6.2
Operation Via LCD Menu (Rev. C Only)
Rev. C of the Cyclone PRO may be operated by making selections from the
LCD menu. This section describes the layout of the menus and the functions
that each may be used to perform.