42
Cyclone PRO User Manual
CYCLONE PRO
5.1.3
Programming Operations
Figure 5-13: Programming Operations Dialog Section
In the Programming Sequence field, the user may specify the algorithm, S-
Record, and operations to be carried out.
Choose Module
Presents a list of available programming files. Each
programming
file contains
information on how to program a particular module. Usually, the name of the
file indicates what kind of module it relates to.
Specify S-Record
Asks for the name (and/or path) to a file of Freescale S-records to be used in
programming or verifying a module. If the file is not found, an error message
is given. The currently-selected file is shown in the
S19
file selected window.
The programmer accepts
S1
,
S2
, and
S3
records. All other file records are
treated as comments. If you do not specify a file-name extension, a default of
.S19 is used. The programmer also supports ELF/Dwarf 2.0 object files.
Your S19 file may contain data for both EEPROM and flash. If you know that
your S19 file contains the correct data, “Ignore S19 Range” may be checked.
This will cause any out of range errors to be ignored.
Erase If Not Blank
This command performs a blank check of the module and erases it if it is not
blank.
Erase Module
If “Erase Module” is specified, the Cyclone PRO will perform an “Erase
Module” on the target device after entering the Monitor Mode or BDM mode.
Blank Check Module