FlexRay Module (FLEXRAYV4)
MFR4310 Reference Manual, Rev. 2
Freescale Semiconductor
169
The trigger bits MBCCSRn.EDT and MBCCSRn.LCKT, and the interrupt enable bit MBCCSRn.MBIE
are not under access control and can be accessed from the application at any time. The status bits
MBCCSRn.EDS and MBCCSRn.LCKS are not under access control and can be accessed from the
FlexRay module at any time.
The interrupt flag MBCCSnR.MBIF is not under access control and can be accessed from the application
and the FlexRay module at any time. FlexRay module set access has higher priority.
The FlexRay module restricts its access to the regions, depending on the current state of the corresponding
part of the double transmit message buffer. The application must adhere to these restrictions to ensure data
consistency. The states for the commit side of a double transmit message buffer are given in
A description of the states is given in
. The states for the transmit side of a double transmit
message buffer are given in
. A description of the states is given in
. The
description tables also provide the access scheme for the access regions.
The status bits MBCCSRn.EDS and MBCCSRn.LCKS provide the application with the required message
buffer status information. The internal status information is not visible to the application.
3.4.6.4.2
Message Buffer States
This section describes the transmit message buffer states and provides a state diagram.
Table 3-101. Double Transmit Message Buffer Access Regions Description
Access
Description
Region
Type
Application
Module
Commit Side
CFG
read/write
-
Message Buffer Configuration
MSG
read/write
-
Message Buffer Data and Control access
ITX
-
read/write
Internal Message Transfer.
SS
-
write-only
Slot Status Update
Transmit Side
CFG
read/write
-
Message Buffer Configuration
SR
-
read-only
Message Buffer Search
TX
-
read-only
Internal Message Transfer, Message Transmission
SS
-
write-only
Slot Status Update
Summary of Contents for FlexRay MFR4310
Page 2: ......
Page 3: ...MFR4310 Reference Manual MFR4310RM Rev 2 03 2008...
Page 6: ...MFR4310 Reference Manual Rev 2 6 Freescale Semiconductor...
Page 12: ...MFR4310 Reference Manual Rev 2 12 Freescale Semiconductor Section Number Title Page...
Page 24: ...MFR4310 Reference Manual Rev 2 24 Freescale Semiconductor Table Number Title Page...
Page 28: ...Introduction MFR4310 Reference Manual Rev 2 28 Freescale Semiconductor...
Page 58: ...Device Overview MFR4310 Reference Manual Rev 2 58 Freescale Semiconductor...
Page 234: ...Clocks and Reset Generator CRG MFR4310 Reference Manual Rev 2 234 Freescale Semiconductor...
Page 260: ...Package Information MFR4310 Reference Manual Rev 2 260 Freescale Semiconductor...
Page 267: ......