Page 3: ...completely HEY Please close the front door OOPS Something s in the way of the cup holder OOPS Wrong cup size HEY The product is not cold enough to be blended WE RE SO SORRY The blender needs to take a...
Page 4: ...p Door to clean off any product build up around the blending chamber rim and gasket Be careful not to damage the gasket Panels Screens 4 2 Daily Blender Maintenance 1 2 Weekly Blender Maintenance Loca...
Page 5: ...ht Arrow OK Recover Catastrophic Error Regular More Thick Initiate Manual Water Shot Rinse Less Thick Initiate Manual Scour Rinse Regular Initiate Manual Rotary Rinse More Thick Initiate Steam Cycle L...
Page 6: ...ting up on the bottom of the Cup Holder If you are unable to raise the Cup Holder replace Position Motor Parts Manual Heaters Position Motor Error 66 Pump Motor Peak Current Limit Exceeded TRIGGER Pum...
Page 7: ...ace Flip Up Door Shoe Parts Manual Switches Sensor Solenoid Lock Error 6B Home Sensor Malfunction During Blend TRIGGER Home sensor blocked or unblocked at the wrong carriage location 1 Reset the blend...
Page 8: ...ns together for 7 seconds to soft reset the blender 2 Check the Scour Thermistor wires and connector The thermistor is located by removing the left right and rear panels The thermistor is located at b...
Page 9: ...ly proceed to Step 10 7 Verify the BF Steamer Heater is heating properly A Verify wiring at the steamer tank is intact and correct B Check for continuity through steamer elements with a Multi Meter a...
Page 10: ...wer c If water is not continuously spraying proceed to Step 6 6 Check that the amount of water dispensed is being accurately registered by the Flow Meter A Remove the Water Shot Hose from the blending...
Page 11: ...tch the Count on Line J of the Status Screen If not replace Flow Meter Parts Manual Water System E If the amount of water in the cup matches the Count on Line J and is still 65mL and error returns ens...
Page 12: ...buttons for 7 seconds until the Status Screen appears on the screen and locate Line E ScrTemp XXX A If the ScrTemp does not reach the Trigger temperatures above or by passes it for more than 1 minute...
Page 13: ...The fuse is located on the LVCB at F1 If the fuse is blown replace LVCB Parts Manual Control Boards Lower 5 Measure DC voltages for the Position Motor on the LVCB at TB5 A At rest Red wire pin to grou...
Page 14: ...re inside the chamber matches the ChmTemp a If the temperatures are the same ensure blender has the latest Firmware Version Press the Left Arrow OK buttons for 7 seconds until the Status Screen appear...
Page 15: ...e Left Arrow OK buttons for 7 seconds until the Status Screen appears on the screen and locate Line J Count XXXX mL a If the amount in the cup is either less or more than what is on the Count XXXX mL...
Page 16: ...the chamber Next remove the right side panel and locate the switch behind the metal tab on the front of the blender 4 Bring up the LVCBS Status Screen Press the Left Arrow OK buttons for 7 seconds un...
Page 17: ...s between 0 6 F A Perform the Squeeze Test Using a chocolate milkshake squeeze the middle of the cup You should be able to squeeze a dime size dent in the milkshake B Ensure the product is tempered se...
Page 18: ...he SBC is a Zotac ensure the USB connections are secure if they are and the issue remains replace with a V1 Single Board Computer Parts Manual Control Boards Lower B If the SBC is a Jetway NC98 2 fans...
Page 19: ...e blender back on at the same time i If the fans start up and the blender boots up in a normal process remove the screwdriver re connect the SBC Reset connection and return the panels ii If the fans s...
Page 20: ...ion Do not slam the door Slamming the door will damage the LCD touchscreen 2 If the door still won t close slowly close the front door and watch where the front door latch meets the blender frame If t...
Page 21: ...shim the wedge out a Add another washer between the back of the LCD screen and Front Door Wedge on the bottom 2 corners This will add more pressure on the bottom of the Front Door Wedge and chamber op...
Page 22: ...hould be able to squeeze a dime size dent in the milkshake ii If you can put a dent in the side of the shake during the squeeze test the product is ready to move into the front display freezer Blender...