background image

3

TROUBLESHOOTING

PROBLEM

PROBABLE CAUSES

CORRECTIVE ACTION

Pump does not turn on.

Pump not plugged in.

Plug in pump.

Circuit breaker shut off or fuse removed.

Turn on circuit breaker or replace fuse.

Accumulation of trash on float.

Clean float.

Float obstruction.

Check float path and provide clearance.

Defective switch.

Have pump serviced by authorized service center.

Defective motor.

Have pump serviced by authorized service center.

Pump will not shut off.

Float or float rod obstruction.

Check float and float rod path and provide clearance.

Pump is air locked.

Shut power off for approximately 1 minute, then restart. Repeat several times to clear air 
from pump.

Liquid inflow matches pump capacity.

Larger pump required.

Defective switch.

Disconnect switch, check w/ohmmeter, Open-infinitive resistance, closed-zero.

Pump runs but does not 
discharge liquid.

Check valve installed backwards.

Check flow indicating arrow on check valve body to ensure it is installed properly.

Check valve stuck or plugged.

Remove check valve and inspect for proper operation.

Lift too high for pump.

Check rating table.

Inlet to impeller plugged.

Pull pump and clean.

Pump is air locked.

(See corrective action above.)

Pump does not deliver 
rated capacity.

Lift too high for pump.

Check rated pump performance.

Low voltage, speed too slow.

Check for proper supply voltage to make certain it corresponds to nameplate voltage.

Impeller or discharge pipe is clogged.

Pull pump and clean. Check pipe for scale or corrosion.

Impeller wear due to abrasives.

Replace worn impeller.

Pump cycles continually.

No check valve in long discharge pipe 
allowing liquid to drain back into basin.

Install a check valve in discharge line.

Check valve leaking.

Inspect check valve for correct operation.

Basin too small for inflow.

Install larger basin.

REPLACEMENT PARTS LIST

ITEM 

NO.

PART NO.

DESCRIPTION

CATALOG NO./ 

MODEL NO.

511610 

                        

HT-10EN-CIM

511710 

                         

HT-10EN-CIA-FS                         

1

109440202 Screen Base

2

109460

Gasket, Screen Base

3

909023

Screw/Washer, 10-24 x 7/8"

5

5

4

950481

Capacitor, 10MFD, 370V

5

950482

Capacitor Bracket

6

928008

Seal Ring, 4.718 ID x .078 Wall

7

901203

Screw, Machine, #6-32 x 1/4"

8

909022

Screw/Washer, 10-24 x 5/8"

4

4

9

950227

Switch Assy, Non Mercury,Automatic

10

951660

Wire Harness Assy, Automatic

 

10

951661

Wire Harness Assy, Manual

11

927427

Loop Clamp, Black

 

12

901424

Screw, Machine, #8-32 x 1/2"

13**

951798

Lead Wire Assembly,White

14**

951799

Lead Wire Assembly,Red

15**

950502

Capacitor Insulating Boot

16**

950400

Closed End Connector

** Items not shown

Summary of Contents for LittleGIANT HT-10EN-CIA-FS

Page 1: ...lure to do so may cause piping to break pump to fail motor bearing failures etc 8 This pump s motor housing is filled with a dielectric oil for motor heat transfer and life time lubrication of the bea...

Page 2: ...may destroy the unit TESTING PUMP OPERATION NOTE BE CERTAIN PUMP IS SECURE IN BASIN AND FLOAT MOVES UNOBSTRUCTED WITHOUT TOUCHING THE BASIN WALLS OR PLUMBING 1 These pumps are equipped with a float o...

Page 3: ...locked See corrective action above Pump does not deliver rated capacity Lift too high for pump Check rated pump performance Low voltage speed too slow Check for proper supply voltage to make certain...

Page 4: ...se were not followed 9 Products connected to voltage other than indicated on nameplate 10 Products where the pump was exposed to any of the following sand gravel cement grease plaster mud tar hydrocar...

Page 5: ...a pompe ou un palier de moteur pourraient d faillir etc 8 Le bo tier du moteur de cette pompe est rempli d une huile di lectrique pour le transfert de chaleur du moteur et la lubrification des paliers...

Page 6: ...ARQUE S ASSURER QUE LA POMPE EST BIEN FIX E DANS LE BASSIN ET QUE LE FLOTTEUR SE D PLACE SANS RESTRICTION ET SANS TOUCHER LES PAROIS DU BASSIN OU LA PLOMBERIE 1 Ces pompes sont munies d un interrupteu...

Page 7: ...e l air Voir la mesure corrective ci dessus La pompe ne fonctionne pas sa capacit nominale L l vation est trop lev e pour la pompe V rifier le rendement nominal de la pompe Faible tension vitesse trop...

Page 8: ...respect es 9 Produits branch s une tension autre que celle indiqu e sur la plaque signal tique 10 Produits o la pompe a t expos e l un des l ments suivants sable gravier ciment graisse pl tre boue go...

Page 9: ...diel ctrico para la transferencia de calor en el motor y proporcionar una lubricaci n de por vida a los rodamientos Este aceite no es t xico para la vida acu tica sin embargo se puede presentar asfix...

Page 10: ...ASEG RESE DE QUE LA BOMBA EST FIJA EN EL DEP SITO Y QUE EL FLOTADOR SE MUEVE SIN OBSTRUCCI N SIN TOCAR LAS PAREDES DEL DEP SITO O LA TUBER A 1 Estas bombas est n equipadas con un interruptor operado p...

Page 11: ...a de arriba La bomba no produce la capacidad clasificada Altura de aspiraci n muy alta para la bomba Revise la clasificaci n de rendimiento de la bomba Bajo voltaje velocidad muy baja Revise para aseg...

Page 12: ...o 9 Productosconectadosalvoltajediferentesalosindicadoenlaplacadeidentificaci n 10 Productos en donde la bomba estuvo expuesta a cualquiera de lo siguiente arena grava cemento grasa yeso lodo alquitr...