8
INSTRUCTIONS FOR ASSEMBLY
15
15.
Remove the pump from the build fixture by
removing the fixture bolt from underneath the
fixture and lifting off the shaft stub. Lay the pump
horizontal on workbench or horizontal support.
CAUTION:
On pumps with higher stage counts,
support center of pump when laying it horizontal to
prevent the pump from bowing.
16.
Check that the pump shaft spins freely by inserting
the appropriate Motor Shaft tool into the coupling
and rotating.
17.
Check that the shaft height is within the defined
range. See Table 3.0 for dimensions. Measure with a
shaft height gauge.
16