38
ENGLISH
INPUT
Enables selecting the input to program from the 4 available:
INPUT 1 / INPUT 2 / INPUT 3 / INPUT 4
ASSOCIATE: enables deciding whether the SAT signal to use for the input being pro
grammed should come from a SAT source directly connected to the CONNECTOR
(LNB or multiswitch) or from a previous input through a LOOP.
NB: using the LOOP as the SAT signal source just one input can be selected for the subsequent
one or for all the subsequent SAT inputs.
For example, if we want to just use INPUT 1 and the LOOP is selected on INPUT2, INPUT3
and INPUT4, all these inputs will receive the SAT signal from INPUT1 with the same polarity
set on INPUT2, and on the remaining inputs only the reception frequency and symbol rate
can be selected. Remember that if there are any reception anomalies on the main module
(SAT transponder with an instable signal and/or which unlocks) there could also be reception
problems on the modules with the LOOP input.
In this case, the LOOP option must be deactivated and the SAT signal taken to all the required
inputs.
Remember that by selecting the LOOP option for an input, the available polarity for the input
will be the same as the one selected for the previous module, should there be any reception
anomalies on the main module (SAT transponder with an instable signal and/or which unlocks)
there could also be reception problems on the modules with the LOOP input.
In this case, the LOOP option must be deactivated and the SAT signal taken to all the required
inputs.