45
ENGLISH
In the address bar type in the IP address associated to the D-MATRIX, here 192.168.0.2; the
opening screen is displayed shown in figure 1, requesting the access data.
Type the username and password (here the factory settings):
Username: admin.
Password: 1234
Press OK to confirm, the screen is displayed shown in figure 2.
Select the language by clicking on the flags at the top right (available in English, Italian, French
and German).
NOTE: the configuration must be made using just one browser window to avoid risk of making
mistakes: therefore two or more configuration cards cannot be opened on the same browser as
the only one that would work would be the last that was opened.
IMPORTANT: to access programming by the web interface, the panel menu must not be used
(D-MATRIX FRACARRO shown on the display).
NOTE: the web interface could change according to the software release installed in the product.
Fig. 1
Fig. 2
The homepage in figure 2 shows the general status of the D-MATRIX system.
The top section shows the input status, displaying the main data about the level and reception
quality parameters (BER/MER) and the name of the transponder received.
Each input also has a led showing the input status, with the following colours:
•
Green if the input is enabled and the receiver is locked (for USB: function enabled and
selected file read correctly).
•
Yellow if the input is enabled but the receiver is not locked (for USB: function enabled but
file missing, not selected or incompatible)
•
Red if the input is remote power feed overload
•
Grey if the input is not enabled
•
The bottom section shows the output mux, in particular the bitrates used overall by the
programs and the bitrates that are still available.
•
The indications are in numeric form and with a horizontal graphic bar.
•
The system also stores the peak bitrate values, and shows whether there has been a bitrate
overflow since the last reset, with a led with the following colours:
•
Green for normal functions
•
Red if there has been a bitrate overflow
If the “reset peak” button is pressed, the peak and overflow details are reset.