6
Hampton® H15U-NG/LP Direct Vent Freestanding Gas Stove
safety label
This is a copy of the label that accompanies
each Direct Vent Freestanding Gas Stove. We
have printed a copy of the contents here for
your review.
NOTE:
Hampton
®
units are constantly being
improved. Check the label on the unit and if
there is a difference, the label on the unit is
the correct one.
920-426
564
564
H15U-NG
Modèle
H15U-NG
H15U-LP
H15U-LP
C# 4001172
APPAREIL FONCTIONNANT AU GAZ PROPANE
APPAREIL FONCTIONNANT AU GAZ NATUREL
Listed:
VENTED GAS FIREPLACE HEATER /
FOYER AU GAZ À ÉVACUATION
Certified to /Certifié : ANSI Z21.88-2019
MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES
AFTER FIRST SALE
Refer to Intertek’s Directory of Building Products for detailed information.
Pour plus de détails, se reporter au Répertoire des produits de construction de Intertek.
3.5
0.87
1.6
0.40
47
18,000
12,700
(5.28 Kw/h)
(3.72 Kw/h)
Model/Modèle :
Pression d’alimentation minimale
Pression manifold élevée
Pression manifold basse
Débit calorifique maximal
Débit calorifique minimal
Taille de l’orifice
Altitude
Pression d’alimentation minimale
Pression manifold élevée
Pression manifold basse
Débit calorifique maximal
Débit calorifique minimal
Taille de l’orifice
Altitude
11
10
2.74
WC/C.E.
2.49
6.4
1.59
18,000
(5.28 Kw/h)
15,500
4.54
55
Model/Modèle :
ÉLECTRICAL SUPPLY/ALIMENTATION ÉLECTRIQUE : 115V_60HZ less than/moins de 2 A.
For Use Only with Barrier (Part #382-005). Follow Installation Instructions.
o
Utiliser uniquement avec un écran de sécurité (pièce n 382-005). Suivre les consignes d’installation.
NOT FOR USE WITH SOLID FUELS / NE PAS UTILISER AVEC UN COMBUSTIBLE SOLIDE
FPI Fireplace Products International Ltd. Delta, BC, Canada
Made in Canada / Fabriqué au Canada
H15U-NG
Modèle
H15U-LP
Left Side Wall
Right Side Wall
Horizontal
Pipe
Left Side Wall
Right Side Wall
Vertical
Pipe
Dégagement par rapport aux matériaux combustibles
Minimum hauteur de plafond sur le dessus de l’appareil :
: 24"/610mm
A 6" / 150mm C 2" / 50mm
B 0"/ 0mm E 2" / 50mm
See Manual for details / Voir manuel pour plus de détails.
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas
and Propane Installation Code, CSA B149.1.This appliance must be installed in accordance with the Standard CAN/CSA Z240 MH, Mobile
Housing, in Canada, or with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the United States, or when
such a standard is not applicable, ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard or ANSI A119.2 ou NFPA
501C Standard for Recreational Vehicles.
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located,
manufactured (mobile) home where not prohibited by local codes. See owner's manual for details. Optional Fan Kit (Part # 382-917)
Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation ANSI Z223.1, National
Fuel Gas Code ou CSA-B149.1 en vigueur.Installer l'appareil selon la norme CAN/CSA-Z240, Série MM, Maison mobiles ou CAN/CSA-Z240 VC,
Véhicules de camping, ou la norme 24 CFR Part 3280, Manufactured Home Construction and Safety Standard. Si ces normes ne sont pas
pertinentes, utilisez la norme ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard, ou ANSI A119.2 ou NFPA 501C
Standard for Recreational Vehicles.
Cet appareil doit être utilisé uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être installé dans une maison
préfabriquée ou mobile (É.-U. seulement) installée à demeure si les règlements locaux le permettent. Voir la notice de l'utilisateur pour plus de
renseignements. Cet appareil ne peut pas être utilisé avec d'autres gaz sauf si une trousse de conversion certifiée est fournie.
Kit du ventilateur en
o
option (Pièce n 382-917)
This vented gas fireplace heater is not for use with air filters. Ne pas utiliser de filtre à air avec ce foyer au gaz à évacuation.
For use with glass doors certified with the appliance only. À utiliser uniquement avec les portes vitrées certifiées avec l'appareil.
For the State of Massachusetts, installation
and repair must be done by a plumber or
gasfitter licensed in the Commonwealth of
Massachusetts.
For the State of Massachusetts, flexible con-
nectors shall not exceed 36 inches in length.
For the State of Massachusetts, the appliances
individual manual shut-off must be a t-handle
type valve.
The State of Massachusetts requires the
installation of a carbon monoxide alarm in
accordance with NFPA 720 and a CO alarm
with battery back up in the same room where
the gas appliance is installed.
Decal location
Fold down access door, and then remove two screws
as shown below
With the panel removed, the gas valve will be visible.
The rating plate will be attached to a black chain
located under the IFC.
DO NOT REMOVE THE DECAL FROM THE UNIT.