installation
Venting Arrangements - Vertical Terminations
with Co-linear Flex System for Residential &
Manufactured Homes into Masonry Fireplaces
Vertical Termination with Co-linear Flex System
THE APPLIANCE MUST NOT BE
CONNECTED TO A CHIMNEY FLUE SERV-
ING A SEPARATE SOLID FUEL
BURNING APPLIANCE.
This appliance is designed to be attached to
two 3" (76mm) co-linear aluminum flex running
the full length of the chimney. See the Venting
Arrangements chart below for minimum and
maximum flue lengths. See chart below for
minimum distances from roof. Periodically check
that the vent is unrestricted.
Masonry chimneys may take various contours which the flexible liner will accommodate. However,
keep
the flexible liner as straight as possible
, avoid unnecessary bending.
The Air Intake pipe must be attached to the inlet air collar of the termination cap.
Straight Vertical Terminations
Required Parts:
Part #
Description
946-529
Co-linear DV Vertical
Termination Cap
948-305
3" Flex - 35 ft.
946-563
Co-Axial to Co-Linear Adapter Kit
which contains the following:
Co-linear Flex Adapter (270-585)
Outer Pipe (946-257)
Inner Pipe Adapter (946-219)
Vent Restrictors
set at fully closed,
Position "B"
Alternate Approved Caps
Part #
Description
46DVA-VC Vertical Termination Cap
OR
46DVA-VCH High Wind Cap
+
46DVA-GK 3" Co-linear Adapter with flashing
The shaded area in the diagram shows the allowable vertical