22
Hampton® H15U-NG/LP Direct Vent Freestanding Gas Stove
installation
H1
H
V
Vertical Venting with Two (2) 90
o
Elbows
Option V
H
V + V1
A)
1' Min. 4' Max. 2' Min.
B)
2' Min. 5' Max. 3' Min.
C)
3' Min. 6' Max. 4' Min.
D)
4' Min. 7' Max. 5' Min.
E)
5' Min. 8' Max. 6' Min.
Vertical Venting with Two (2) 90
o
Elbows
With these options, max. total
pipe length is 30 feet with min.
of 6 feet total vertical and max.
8 feet total horizontal.
Please note min. 1 foot be-
tween 90
o
elbows is required.
Option H + H1 V
A)
2' Max. 2' Min.
B)
3' Max. 3' Min.
C)
4' Max. 4' Min.
D)
5' Max. 5' Min.
E)
6' Max. 6' Min.
With these options, max. total
pipe length is 30 feet with min.
of 6 feet total vertical and max.
6 feet total horizontal.
Please note min. 1 foot
between 90
o
elbows is
required.
One 90
o
elbow = Two 45
o
elbows.
One 90
o
elbow = Two 45
o
elbows.
V1
V
H
Vent restrictor position A (fully open), refer to the "Vent
Restrictor Postion" section.
Vent restrictor position A (fully open), refer to the
"Vent Restrictor Postion" section.
Lengths do not include elbow indicated
Lengths do not include elbow indicated