FPI FP90 Wood Fireplace
33
HEA
TW
A
VE KIT
HEATWAVE KIT (NOT EPA APPROVED)
Diagram 4
4)
Install the variable speed Wall Rheostat (with
OFF setting) in a convenient location. This
switch controls the fan operation.
5)
Wire 120V AC service to the Wall Rheostat
and from the Wall Rheostat to the Fan
Junction Box. Use wire nuts to secure the
120V AC wires to the hot and neutral fan
wires and screw the 120V AC ground wire
to the Fan Junction Box. See wiring diagram
below.
6)
Screw the fan junction box to the fan
housing.
7)
Screw the Register Adapter Frame and the
Air Register to the Fan Housing, diagram 4
below.
Oval Air Duct
: Attach the round-to-oval
adaptor to the fi replace starting collar and
a 6" oval duct (not supplied) to the adaptor.
Complete the duct run and attach the oval
duct to the fan housing.
Round and Oval Duct:
A combination of
6" round and 6" oval duct can be used in
the duct run. Oval duct components are
not supplied but can be purchased from an
HVAC supplier.
OPERATION
1)
Start the fi replace as per instructions and
allow it to warm up.
2)
Turn the Wall Rheostat "ON" and adjust the
variable speed based upon desired air fl ow
at the Air Duct Register.
MAINTENANCE
1)
Service and maintain the fi replace as per
the fi replace installation manual.
2)
Keep the Air Register(s) clean and free of
any blockage.
Note: For new construction only the
Air Register is required to cover the
opening.
8)
Complete the fi replace installation as per
fi replace installation manual.
Ground Lug
CAUTION: Label all wires prior
to disconnection when servicing
controls. Wiring errors can
cause improper and dangerous
operation.
Caution: Ensure that the wires do
not touch any hot surfaces and are
away from sharp edges.
NOTE:
The wires (in dotted lines) and
wire nuts are supplied by others.
IMPORTANT: If the internal blower is installed, it cannot be operated if the Heat Wave air duct kit fan is operating.
WIRING DIAGRAM
Do not cut the ground terminal off
under any circumstances.
Diagram 3