FPI FP90 Wood Fireplace
16
INST
ALLA
TION
Plan View
Jakel AX-2495 Blower
Angle View
Fan Transfer Plate
Right View
Front View
Fan 910-175 AX-3088
910-903
910-516
Ground
Neutral - from Fan
910-811
Thermodisc 910-142 P60T12
Variable Switch 910-330
919-885
Power Chord 910-619
Ground
Hot - to Va
riable Switch
WIRING THE FP90
Field wire main power supply to fi replace blower
system. (All electrical connections should
only be performed by a licensed/certifi ed
electrician).
CAUTION: Label all wires prior to
disconnection when servicing controls.
Wiring errors can cause improper and
dangerous operation.
INSTALLING THE
BLOWER SYSTEMS
The FP90 Fireplace has been designed to
meet a wide range of heating requirements.
The radiant heat (through the large glass area)
combined with the naturally convected heat,
allows the FP90 Fireplace to adequately heat an
average sized room. A blower is recommended
to assist in heating a larger area or one with wall
separations. Through the use of two separate
blower systems, Regency has developed
the basic blower wiring options listed in the
diagrams shown.
GRAVITY AIR FEED KIT OPTION
The Gravity Air Feed Kit is designed to extend the heat output vent
above the FP90 to the front or the side. The upper louver opening
is blocked off and fl ex vent is connected to the vent holes in the
top of the unit and run to discharge vent grilles. Both 8" (203mm)
diameter insulated Flex vents must be used along with one 30 sq.
inch (194cm
2
) chase vent grill to bring additional air into the chase
(for U.S. installations only).
Qty Description
4
Connector
Collars
4
Adjustable
Clamps
2
5’ lengths of fl exible vent pipe
(8”
dia.)
2
Insulated
Sleeves
1
Block Off Plate
2
Discharge Vent Mounting Frames
7
1/4-20 x 1/2” Truss Head Screws
(used for EX90/R90 only)
2
16 x 8 Discharge Vent Grilles
4
#8
Drywall
Anchors
4
Insulation
Strips
1
Chase
Vent
Frame
(not required for FP90)
1
8 x 8 Chase Vent Grille
(not required for FP90)
Discharge Vent
Grill
Chase Vent
Grill
30 sq.in. (194 sq.cm)
opening
Alternate Position for
Chase Vent Grill
Block-off Plate
(replace top louver)
Base of Stove
Vent Cover 'B'
(Inside)
Vent Cover 'A"
Center-line
of Vent
6" (152mm) Min.
To Rouch Opening
Ceiling
Flue
Flex Vent
Clamp
Connector
Collar
Connector
Collar
Outside Air
Intake
Insulation
Strips
INSTALLATION
Internal Blower with Thermo-Disc
The thermodisc provides the user with more convenient control. The fan operates automati-
cally - turn the knob to adjust to desired speed. The fan will turn on as the stove comes up to
operating temperature. After the fi re cools to below a useful heat output range the fan will shut
off automatically.
Place sticker on outside of bottom louver.