FPI FP90 Wood Fireplace
31
HEA
TW
A
VE KIT
HEATWAVE KIT (NOT EPA APPROVED)
Diagram 1: Guide for possible air duct runs and locations. Keep duct length and number of
bends to a miniumum. Maximum duct length is 20 ft. (6.1m) per kit.
LISTINGS AND CODE
APPROVALS
This Kit has been approved for use with
Models EX90 / R90. This kit has been tested in
accordance with National Safety Standards, and
has been certifi ed by OMNI Test Laboratories
for installation and operation in Canada as
described in these Installation and Operating
Instructions.
Check with your local building code agency
before you begin your installation to ensure
compliance with local codes, including the
need for "permits" and follow-up inspections. If
any problems are encountered regarding code
approvals, or if you wish clarifi cation on any of
the instructions contained here, contact your
local dealer.
GENERAL
INFORMATION
The Heat Wave Air Duct Kit increases the
effectiveness of your fi replace by dispersing
warm air from the fi replace to remote locations in
the same room or other rooms in your home.
Up to two kits may be installed on the fi replace.
Please Note:
Only 1 HeatWave kit may be
operated at one time. This includes the internal
blower option as well.
Important Installation Notes
1)
The appliance installation must conform
with local codes or, in the absence of local
codes, with the current Canadian or National
Gas Codes, CAN1-B149 or ANSI Z223.1
Installation Codes.
2)
The appliance when installed, must be
electrically grounded in accordance with
local codes, or in the absence of local codes
with the current National Electrical Code,
ANSI/NFPA 70 or CSA C22.1 Canadian
Electrical Code.
3)
This kit is tested and safe when installed in
accordance with this installation manual.
Please read all instructions before starting
installation and follow all instructions
carefully during installation.
4)
Installation of this kit must be performed by
a qualifi ed service technician.
5)
The Heat Wave Kit must be installed only
as specifi ed. Any modifi cations of the kit or
components will void the warranty and may
cause a fi re hazard.
6)
Plan the location of the fi replace and the
warm air duct runs, see diagram 1 as a
guide for possible duct runs and locations.
Maximum Duct Run: 20 ft. (6.1m) per
kit.
NOTE:
Airfl ow through the duct system is
affected by the duct length and number of
bends. Keep the length and bends to a
minimum to maximize performance.
PARTS
Included with Kit:
1 946-010 20 ft. (6.1 m) of 6" dia. fl ex pipe
1 946-517 Fan housing assembly
1 910-412 Variable
wall
rheostat
1 946-006 Air
register
1 946-005 Register adaptor frame (thick)
1 946-000 Round Duct collar
1 946-001 Oval Duct collar
1 946-002 Duct adaptor (round to oval)
1 946-045 Insulation
(60")
Hardware package
If any parts are missing or damaged, contact
your dealer before starting installation. DO
NOT install a damaged kit.