CABINETS - OPERATION
Switch Power
On
Turn on the power switch, the compressor will
run, and the cabinet temperature will begin to
fall.
The temperature controller is pre-set to maintain
the cabinet temperature at 2
- 4
C. It should
not need adjustment.
Load Cabinet
After the cabinet has run for a 30 minute initial cool-down period, load it with
pre-chilled product.
The cabinet is designed to maintain the temperature of pre-chilled product at
between 2
and 4
C.
If warm product is introduced, there could be a delay before the
temperature falls to the normal operating level.
Air Baffle
Plates
If low profile products are displayed on any shelf,
fit an air baffle plate to block the upper back
panel air slots behind that shelf.
This will maintain correct cool air flow among the
products.
The plate should be fitted in the location slots
immediately below the shelf brackets.
Loading
Restrictions
It is important to leave adequate free space for the refrigerated air to circulate
within the cabinet.
The air grills at the front of the cabinet must not be covered or restricted.
Defrost Cycle
Defrosting of the evaporator coil is fully automatic. Measurements of air and coil
temperatures control the commencement and duration of the defrost cycles.
This active defrost system improves the energy efficiency of the cabinet, and
minimises temperature fluctuations.