Part No. 20862 Rev. G February 2015
- 20 -
Chilled Cabinets
Mandatory Cleaning Routines
CABINETS
-
CLEANING
Warning
It is mandatory to have the radiator fins cleaned periodically, by a
refrigeration engineer. (see Servicing section)
.
Failure to carry out routine cleaning/servicing schedules will void the
warranty on the refrigeration equipment.
To maintain optimum performance, cleaning must be regular and thorough.
It is recommended that a schedule of cleaning operations should be drawn up.
Condenser
Radiator
For efficient refrigeration performance, the
condenser radiator must be clean. To
access the radiator, the bottom panel must
be removed from
the back of the
cabinet, so this
would normally be
done by a service person, rather than the
operator.
Be careful not to disturb the location of the air temperature sensing probe.
Condenser
Fans and Air
Duct
The bottom side panels must be removed to
access the two condenser fans, so this
would also normally be done by a service
person.
The fan units pull out from either side of the
cabinet, and can be unplugged and taken
away for easy cleaning.
Vacuum away any dust and fluff in the duct.
Inspection and
Rectification
As part of the cleaning routine, the controls, mechanical parts and electrical
wiring should be inspected for damage, deterioration or need of adjustment.
If any small faults are found, have them attended to promptly by a competent
serviceman. Don’t wait until they cause a complete breakdown.